SKU: SENS-0839
📋 GST Invoice Available

Mastech MS6310 Combustible Gas Analysis Apparatus - Portable Gas Leak Detector

₹7,169.00 (Inclusive of all taxes)
Out of Stock

The Mastech MS6310 is a portable combustible gas analysis apparatus designed for professional detection of flammable gas leaks. It operates on 4x AA batteries and features audible/visual alarms for immediate hazard notification in industrial and residential safety applications.

Features

  • High-sensitivity catalytic bead sensor for detecting a wide range of flammable gases including methane, propane, hydrogen, and solvents.
  • Portable, battery-powered design with a durable housing for on-site inspections and safety checks.
  • Configurable audible and visual alarms triggered at 10% to 40% of the Lower Explosive Limit (LEL).
  • Fast warm-up time of approximately 2 minutes for rapid deployment in emergency or routine monitoring scenarios.
  • Includes a protective carry bag, batteries, and user manual for immediate field use.

Out of stock

Description

The Mastech MS6310 Combustible Gas Analysis Apparatus employs a robust catalytic combustion sensor to detect the presence of flammable gases. This principle ensures reliable measurement of gas concentration as a percentage of the Lower Explosive Limit (LEL), providing a critical safety margin for leak assessment. The unit is engineered for durability and portability, making it a vital tool for HVAC technicians, industrial safety officers, and facility maintenance teams.

Designed for straightforward operation, the MS6310 requires minimal warm-up time and delivers a clear response to gas presence. Its alarm system is configurable within a 10% to 40% LEL range, allowing for customization based on specific site safety protocols. The apparatus serves as an essential first line of defense in preventing fire and explosion hazards across various environments.

Key Features

  • Catalytic bead sensor technology for broad-spectrum flammable gas detection.
  • Dual-mode alarm system with loud audible buzzer and bright visual LED indicator.
  • User-configurable alarm threshold settings from 10% to 40% LEL for tailored safety monitoring.
  • Optimized for portability with a compact, ergonomic design powered by standard AA batteries.
  • Fast 2-minute warm-up period enables quick readiness for emergency inspections.
  • High-value build with a rugged casing suitable for demanding industrial and field conditions.
  • Simple two-button interface for power, calibration, and alarm range selection.
  • Includes a dedicated carry bag for convenient transport and storage of the unit and accessories.

Applications

  • Preventive maintenance and leak detection in residential and commercial natural gas/LPG piping systems.
  • Safety compliance checks in industrial facilities handling flammable solvents, fuels, or hydrogen.
  • HVAC system inspection to identify combustible gas accumulation in confined spaces or ducts.
  • Emergency response and first-responder tool for initial hazard assessment at suspected leak sites.
  • Automotive and marine workshop safety for detecting fuel vapor leaks in engine bays and bilges.

Technical Specifications

Model NumberMS6310
Detection PrincipleCatalytic Combustion (LEL)
Power Supply4 x 1.5V AA Batteries
Alarm Range10% ~ 40% LEL (Configurable)
Warm-Up TimeApprox. 2 Minutes
Detectable GasesMethane, Propane, Hydrogen, Gasoline, Solvents, CO (Combustible)
Alarm IndicatorsAudible Buzzer & Visual LED
Dimensions (L x W)172 mm x 70 mm
Unit Weight (Approx.)~0.5 kg (Unit Only)

Frequently Asked Questions

What types of gases can the Mastech MS6310 detect?

The MS6310 is designed to detect a wide range of flammable gases and vapors using its catalytic combustion sensor. This includes common fuels like methane (natural gas), propane, hydrogen, gasoline, jet fuel, and various industrial solvents. It measures the concentration as a percentage of the Lower Explosive Limit (LEL), providing a safety-focused reading rather than a precise PPM value for specific gases.

How do I set the alarm threshold on the MS6310?

The alarm threshold on the MS6310 is user-configurable between 10% and 40% of the LEL. Typically, you use the function buttons on the device to enter a setting mode and select your desired alarm level. It is crucial to consult the included user manual for the exact button sequence, as setting the appropriate threshold is vital for aligning with your site's specific safety protocols and response requirements.

What is the power source and battery life for this gas detector?

The apparatus is powered by four standard 1.5V AA batteries. Battery life depends heavily on usage frequency and alarm activity. For intermittent use during inspections, a set of alkaline batteries can last for many operational hours. For critical or continuous monitoring applications, it is recommended to use high-quality batteries and check the device's power indicator regularly to ensure reliable operation.

Is the MS6310 suitable for use in confined spaces?

Yes, its portable and compact design makes it suitable for preliminary atmospheric checks in confined spaces. However, for entry into permit-required confined spaces, regulations often mandate the use of multi-gas detectors with specific sensors (e.g., for O2, H2S, CO). The MS6310 serves as an excellent tool for initial leak detection and monitoring of combustible hazards in such environments as part of a broader safety plan.

Package Includes

  • 1 x Mastech MS6310 Combustible Gas Analysis Apparatus
  • 1 x Protective Carry Bag
  • 1 x Set of AA Batteries
  • 1 x User's Manual

Additional Information

Weight 0.5 kg
Dimensions 17.2 × 7 cm