The FirstRate ST100-ZD102 is a high-precision turbidity sensor designed for industrial water quality monitoring, featuring a 0-4000 NTU measurement range with 4-20mA analog and RS485 Modbus digital outputs for seamless integration into PLCs, SCADA systems, and data acquisition units.

Features

  • High-precision turbidity measurement across a 0-4000 NTU range with ±5% FS accuracy.
  • Dual output signals: industry-standard 4-20mA analog and RS485 Modbus-RTU digital communication.
  • Robust 316 stainless steel construction with IP68 rating for durability in harsh, submerged environments.
  • Wide operating temperature range from 0 to 80°C, suitable for diverse industrial processes.
  • Includes a 5-meter cable for flexible installation in tanks, pipelines, and treatment systems.

Out of stock

Description

The FirstRate ST100-ZD102 turbidity sensor employs a nephelometric optical sensing principle, where a light source illuminates suspended particles in a liquid and a photodetector measures the scattered light intensity. This method provides reliable and repeatable turbidity readings critical for process control and water quality compliance. The sensor’s signal conditioning electronics deliver stable, low-noise outputs suitable for long-distance transmission in industrial settings.

Encased in corrosion-resistant 316 stainless steel and rated IP68, the sensor is built to withstand continuous immersion, high-pressure washdowns, and chemically aggressive environments. Its wide 9-30 VDC input voltage range, with 12 VDC recommended, ensures compatibility with standard industrial power supplies, making it a versatile solution for monitoring clarifiers, filter effluents, and raw water intakes.

Key Features

  • High-precision optical turbidity sensing with 0.01% resolution for detailed process monitoring.
  • Dual-output flexibility: 4-20mA for simple analog loops and RS485 Modbus for networked, multi-drop digital systems.
  • Industrial-grade 316L stainless steel housing provides superior corrosion resistance in chemical and marine applications.
  • IP68 submersible protection ensures reliable operation in fully submerged installations up to 3 bar pressure.
  • Wide operating temperature range (0-80°C) for stability in both cold inlet water and heated process streams.
  • Low power consumption (≤10W) and broad 9-30 VDC input for easy integration into existing control panels.
  • Pre-calibrated for quick deployment, reducing installation time and startup costs.
  • Includes a 5-meter shielded cable with integral connector for immediate connection to junction boxes or transmitters.

Applications

  • Continuous turbidity monitoring in municipal drinking water treatment plants and wastewater effluent compliance.
  • Process control in chemical and pharmaceutical manufacturing for batch clarity and filtration efficiency.
  • Protection of reverse osmosis (RO) membranes and ion exchange beds in power plant water purification systems.
  • Monitoring of filter backwash cycles and final product quality in food and beverage production.
  • Environmental monitoring in rivers, lakes, and industrial discharge points for regulatory reporting.

Technical Specifications

Model NumberFST100-ZD102
Measurement Range0 - 4000 NTU
Accuracy±5% of Full Scale (FS)
Resolution0.01%
Output Signals4-20mA, RS485 (Modbus-RTU protocol)
Input Voltage9 - 30 VDC (12 VDC recommended)
Power Consumption≤ 10 W
Operating Temperature0 to 80 °C
Operating Humidity< 90% RH (non-condensing)
Housing Material316 Stainless Steel
Pressure RatingWithstands up to 3 bar
Ingress ProtectionIP68
Cable Length5 meters
Shipping Weight1.5 kg
Shipping Dimensions15 cm (W) x 15 cm (D) x 20 cm (H)

Frequently Asked Questions

What is the power supply requirement for the ST100-ZD102 sensor?

The sensor operates on a wide-range DC input of 9 to 30 volts, with 12 VDC being the recommended voltage for optimal performance. It has a maximum power consumption of 10 watts. Ensure your power supply is stable and properly rated for the installation environment.

How do I connect and communicate with the sensor's RS485 output?

The RS485 interface uses the standard Modbus-RTU protocol. Connect the sensor's A and B wires to your RS485 network, ensuring proper termination and bias resistors if required for long cable runs. You can then poll the sensor's register map using a Modbus master (PLC, SCADA, or data logger) to read turbidity values and other parameters.

Is this sensor suitable for continuous submersion?

Yes, with its IP68 rating and 316 stainless steel construction, the ST100-ZD102 is designed for continuous submersion and can withstand pressures up to 3 bar. It is ideal for direct installation in tanks, pipelines, and open bodies of water for permanent monitoring.

What is the difference between the 4-20mA and RS485 outputs?

The 4-20mA analog output provides a simple, noise-resistant signal proportional to the turbidity reading, ideal for connecting directly to a PLC analog input or chart recorder. The RS485 digital output provides two-way communication, allowing you to read detailed data, configure parameters, and connect multiple sensors on a single bus, which is better for networked systems.

Does the sensor require calibration, and how is it performed?

The sensor is pre-calibrated from the factory. Field calibration can be performed using standard formazin turbidity standards to adjust for specific application conditions or to verify accuracy over time. Calibration typically involves applying known standard solutions and adjusting the sensor's output via its software interface or configuration registers over the RS485 connection.

Package Includes

  • 1 x FirstRate ST100-ZD102 Turbidity Sensor
  • 1 x 5-meter integrated connection cable

Additional Information

Weight 1.5 kg
Dimensions 15 × 15 × 20 cm