SKU: SENS-0832
📋 GST Invoice Available

Renke RS-CO2-N01-2-5000P Carbon Dioxide Sensor, 0-5000ppm, -40°C to 80°C, RS485 Modbus

₹7,629.00 (Inclusive of all taxes)
Out of Stock

The Renke RS-CO2-N01-2-5000P is an industrial-grade NDIR carbon dioxide sensor module featuring RS485 Modbus output for direct integration with PLCs, SCADA systems, and industrial automation controllers. It provides accurate CO2 concentration measurement from 0 to 5000 ppm across a wide operating temperature range of -40°C to 80°C.

Features

  • High-precision NDIR sensing for 0-5000 ppm CO2 concentration.
  • Industrial RS485 Modbus communication interface for robust data transmission.
  • Wide operating temperature range from -40°C to 80°C for harsh environments.
  • 10-30V DC wide-range power supply with low average current consumption (<85 mA).
  • Compact, rugged housing designed for easy panel or duct mounting.

Out of stock

Description

The RS-CO2-N01-2-5000P utilizes a non-dispersive infrared (NDIR) sensing principle for stable and reliable carbon dioxide detection, offering immunity to sensor poisoning and long-term drift. Its integrated signal conditioning circuit provides a fully isolated output, ensuring safe and reliable operation when connected to industrial control systems.

Designed for continuous monitoring, the sensor features a fast 2-second data update time and a warm-up period of 2 minutes for available readings, reaching maximum precision within 10 minutes. Its robust construction and wide operating temperature range make it suitable for deployment in challenging environments such as communication rooms, warehouses, and HVAC ducts.

Key Features

  • NDIR (Non-Dispersive Infrared) sensing technology for high accuracy and long-term stability.
  • RS485 Modbus RTU communication protocol for seamless industrial network integration.
  • Wide-range 10-30V DC power input compatible with standard industrial power supplies.
  • Fully isolated design separating power, sensing unit, and signal output for enhanced safety.
  • High linearity (<1% F.S.) and excellent stability (<2% F.S.) over the measurement range.
  • Ruggedized construction for reliable operation in temperature extremes from -40°C to 80°C.
  • Compact form factor (16 x 16 x 6 cm) for flexible installation in confined spaces.

Applications

  • HVAC system demand-controlled ventilation (DCV) and indoor air quality (IAQ) monitoring.
  • Industrial safety and environmental monitoring in warehouses and manufacturing facilities.
  • Data center and server room environmental control for equipment protection.
  • Agricultural greenhouse CO2 enrichment control and growth optimization.
  • Building automation and energy management systems for smart building compliance.

Technical Specifications

Manufacturer Part NumberRS-CO2-N01-2-5000P
Measurement PrincipleNDIR (Non-Dispersive Infrared)
Measurement Range0 to 5000 ppm CO2
Output InterfaceRS485 (Modbus RTU)
Power Supply10 to 30 V DC
Average Current< 85 mA
Operating Temperature-40°C to 80°C
Data Update Time2 seconds
Warm-up Time2 minutes (available), 10 minutes (max precision)
Non-Linearity< 1% F.S.
Stability< 2% F.S.
Dimensions (L x W x H)16 cm x 16 cm x 6 cm
Weight0.18 kg

Frequently Asked Questions

What is the communication protocol for this CO2 sensor?

This sensor uses the RS485 serial interface with the Modbus RTU communication protocol. It requires a Modbus-capable master device (like a PLC, industrial gateway, or microcontroller with a MAX485 module) to read the CO2 concentration data. The specific register addresses and data format are detailed in the manufacturer's Modbus register map.

What is the required power supply and how do I wire it?

The sensor operates on a wide-range 10-30V DC power supply, with an average current draw of less than 85 mA. You must connect the positive and negative power leads to the designated terminals on the sensor. The RS485 data lines (A/B or D+/D-) should be connected to your host device's RS485 port, ensuring proper termination and bias resistors are configured on the bus for reliable communication over long distances.

How long does the sensor take to provide an accurate reading after power-on?

The sensor provides a usable reading approximately 2 minutes after power-on. For maximum precision and stability, a full warm-up period of 10 minutes is recommended. The integrated NDIR sensing element and optical bench require this time to reach thermal equilibrium, ensuring readings are within the specified accuracy and stability limits.

Can this sensor be used outdoors or in unconditioned spaces?

Yes, its extended operating temperature range of -40°C to 80°C and robust construction make it suitable for challenging environments, including unconditioned warehouses, agricultural settings, and external air intake monitoring. Ensure the unit is mounted in a location protected from direct water immersion, as the IP rating should be verified from the official datasheet for specific environmental protection levels.