SKU: SENS-0814
📋 GST Invoice Available

Plantower PMS5003 PM2.5 Laser Particle Concentration Sensor, UART, 0~500 µg/m³, 5 V, Range: 0.3~10 µm

₹2,119.00 (Inclusive of all taxes)
Out of Stock

The Plantower PMS5003 is a digital laser Particle concentration sensor with a UART interface, designed for real-time measurement of airborne particulate matter (PM1.0, PM2.5, PM10) from 0.3 to 10 µm. Operating at 5V DC, it provides direct digital output for seamless integration with microcontrollers like Arduino, Raspberry Pi, and industrial monitoring systems.

Features

  • Laser scattering principle for precise Particle concentration measurement (0.3–10 µm).
  • Digital UART serial interface for direct, calibrated data output.
  • Wide measurement range up to ≥1000 µg/m³ with high sensitivity.
  • Patented six-sided shielding ensures high anti-interference performance.
  • Compact, fan-less design with flexible airflow inlet/outlet configuration.

Out of stock

Description

The Plantower PMS5003 sensor utilizes a laser scattering detection method to count and size airborne particles in real-time. It outputs digital concentration data for PM1.0, PM2.5, and PM10 via a standard UART serial interface, eliminating the need for external analog signal conditioning. The sensor’s internal algorithm ensures a zero false alarm rate, providing reliable data for environmental monitoring.

Engineered with a patented six-sided shielding structure, the PMS5003 minimizes electromagnetic interference, ensuring stable operation in electrically noisy environments. Its compact, fan-less design allows for flexible integration into air quality monitors, HVAC systems, and portable environmental sensing devices, operating from a 4.5V to 5.5V DC power supply.

Key Features

  • Laser-Based Detection: Employs a laser diode and photodetector for high-sensitivity Particle counting from 0.3 micrometers.
  • Digital UART Output: Provides calibrated, ready-to-use Particle concentration data (PM1.0, PM2.5, PM10) over serial communication.
  • High Anti-Interference Design: Features patented six-sided electromagnetic shielding for stable performance in complex electrical environments.
  • Real-Time Response: Delivers continuous, updated concentration readings with a fast response time.
  • Wide Operating Voltage: Compatible with standard 5V logic systems, accepting 4.5V to 5.5V DC input.
  • Compact & Fan-Less: Space-efficient design without moving parts, suitable for embedded applications.
  • Flexible Airflow Configuration: Allows adaptation of air inlet and outlet orientation to fit various enclosure designs.

Applications

  • Indoor and outdoor air quality monitoring stations and portable detectors.
  • HVAC system air filter efficiency monitoring and control.
  • Integration into smart home environmental control and ventilation systems.
  • Industrial workplace safety and occupational health particulate monitoring.
  • Scientific research and data logging for atmospheric studies.

Technical Specifications

Detection PrincipleLaser Scattering
Particle Size Range0.3 ~ 10 µm
Measurement Range (Mass Concentration)0 ~ ≥1000 µg/m³
Output InterfaceUART (TTL Level)
Power Supply Voltage4.5 ~ 5.5 V DC
Operating Current≤100 mA (Typical)
Response Time<10 seconds
Standby Current≤200 µA
Operating Temperature Range-10 ~ +60 °C
Storage Temperature Range-40 ~ +80 °C
Dimensions (L x W x H)Approx. 50 x 38 x 21 mm (Sensor Unit)

Frequently Asked Questions

What is the output format of the PMS5003 sensor?

The PMS5003 outputs digital Particle concentration data via a UART serial interface at TTL logic levels (0V/5V). It transmits structured data packets containing PM1.0, PM2.5, and PM10 concentration values in µg/m³, which can be directly parsed by microcontrollers like Arduino or Raspberry Pi without analog-to-digital conversion.

What is the required power supply for the PMS5003?

The sensor requires a DC power supply between 4.5V and 5.5V, with a typical operating current of less than 100mA. It is designed for standard 5V systems. Ensure a stable power source, as voltage fluctuations can affect the laser diode's performance and measurement accuracy.

How do I connect and communicate with the PMS5003 using an Arduino?

Connect the sensor's VCC to Arduino 5V, GND to GND, and the TX pin of the sensor to a software serial RX pin on the Arduino (e.g., pin 10). Use a serial library to read the incoming data packets. You will need to implement or use an existing library to correctly decode the 32-byte data frames to extract the PM concentration values.

What Particle sizes can the PMS5003 detect?

The sensor is capable of detecting and differentiating airborne particles with diameters ranging from 0.3 micrometers (µm) up to 10 micrometers (µm). It specifically reports the mass concentration of particles in the PM1.0, PM2.5, and PM10 size categories, which are standard metrics for air quality assessment.

Does the sensor require any calibration or maintenance?

The PMS5003 is factory calibrated and does not require user calibration. For maintenance, ensure the laser window and air pathways remain unobstructed by dust or debris, which can degrade accuracy over time. The sensor has no user-serviceable parts and is designed as a sealed unit.

Package Includes

  • 1 x Plantower PMS5003 Laser Particle Sensor Module

Additional Information

Weight 0.045 kg