SKU: SENS-0778
📋 GST Invoice Available

JXBS-3001-TVOC-RS-6 Wall-Mounted Air Quality Sensor - RS485, 4G, NB-IoT, LoRa

₹5,059.00 (Inclusive of all taxes)
Out of Stock

The JXBS-3001-TVOC-RS-6 is a multi-parameter wall-mounted air quality sensor providing real-time monitoring of TVOC, eCO2, temperature, and humidity. It features versatile industrial communication interfaces including RS485, 4G, NB-IoT, and LoRa for integration into smart building systems, industrial PLCs, and IoT platforms.

Features

  • Multi-parameter sensing for TVOC, eCO2, temperature, and humidity.
  • Multi-protocol industrial connectivity: RS485, 4G, NB-IoT, and LoRa.
  • Wall-mounted ABS housing designed for commercial and industrial environments.
  • Wide operating temperature range from -20°C to 60°C.
  • Low power consumption (≤50mA) suitable for continuous monitoring.

Out of stock

Description

The JXBS-3001-TVOC-RS-6 is an integrated environmental monitoring sensor designed for comprehensive indoor air quality assessment. It utilizes advanced sensing elements to provide accurate, real-time data on Total Volatile Organic Compounds (TVOC), equivalent carbon dioxide (eCO2), ambient temperature, and relative humidity. This data is critical for maintaining healthy indoor environments and optimizing HVAC system performance.

Engineered for industrial and commercial deployment, the sensor features a robust wall-mounted ABS enclosure. Its multi-interface communication suite, including RS485 Modbus, 4G, NB-IoT, and LoRa, offers flexible integration options for building automation systems, environmental monitoring networks, and cloud-based IoT platforms, enabling proactive air quality management and data-driven decision-making.

Key Features

  • Four-in-one sensing capability for comprehensive air quality analysis.
  • Industrial-grade communication protocols (RS485/Modbus, 4G, NB-IoT, LoRa) for versatile system integration.
  • Durable wall-mounted ABS housing designed for long-term reliability in diverse environments.
  • High-sensitivity detection for precise TVOC and eCO2 concentration monitoring.
  • Wide operating temperature range (-20°C to +60°C) ensures performance in various climates.
  • Low power consumption design supports continuous, unattended operation.
  • Real-time data transmission enables immediate alerts and automated control responses.
  • Easy installation and configuration for rapid deployment in commercial spaces, factories, and public buildings.

Applications

  • Smart Building & HVAC Control: Continuous monitoring for automated ventilation and air purification systems.
  • Industrial Workplace Safety: Real-time TVOC and air quality monitoring in factories, workshops, and laboratories.
  • Commercial Space Management: Ensuring air quality compliance and occupant comfort in offices, schools, and retail spaces.
  • IoT Environmental Monitoring Networks: Deploying sensor nodes for city-wide or facility-wide air quality mapping using 4G/NB-IoT/LoRa.
  • Indoor Air Quality (IAQ) Certification & Auditing: Providing verifiable data for health, safety, and green building standards.

Technical Specifications

Item TypeGas Sensor
Model NumberJXBS-3001-TVOC-RS-6
Operating Voltage12V DC
Current Consumption≤ 50 mA
Operating Temperature-20°C to 60°C
Housing MaterialABS Shell
MountingWall-Mounted
Communication InterfacesRS485, 4G, NB-IoT, LoRa
Sensing ParametersTVOC, eCO2, Temperature, Humidity
Length250 mm
Width200 mm
Weight350 g

Frequently Asked Questions

What communication protocols does this sensor support?

The JXBS-3001-TVOC-RS-6 supports multiple industrial and IoT communication protocols. It includes a wired RS485 interface, typically using the Modbus RTU protocol, for direct connection to PLCs or SCADA systems. For wireless deployment, it integrates 4G cellular, NB-IoT, and LoRaWAN modules, providing flexible options for remote data transmission to cloud platforms.

What parameters does this sensor measure?

This is a multi-parameter sensor designed for comprehensive indoor air quality assessment. It measures the concentration of Total Volatile Organic Compounds (TVOC), calculates equivalent Carbon Dioxide (eCO2) levels based on VOC readings, and simultaneously monitors ambient temperature and relative humidity. All data points are output concurrently via the selected communication interface.

What is the power requirement and how is it installed?

The sensor operates on a 12V DC power supply with a typical current consumption of ≤50mA. It is designed for wall-mounted installation using its integrated ABS housing. The specific mounting hardware may vary, but the unit is typically secured via screw holes on the backplate. Ensure installation in a representative location for accurate air sampling, away from direct airflow from vents or windows.

Is this sensor suitable for outdoor use?

While the sensor has a wide operating temperature range of -20°C to 60°C, its standard ABS housing and lack of a specified IP rating for waterproofing indicate it is primarily designed for indoor or protected outdoor environments. For fully exposed outdoor applications, additional protective enclosures or verification of environmental sealing would be required.

Package Includes

  • 1 x JXBS-3001-TVOC-RS-6 Wall-Mounted Air Quality Sensor

Additional Information

Weight 0.35 kg
Dimensions 25 × 20 cm