SKU: SENS-1355
📋 GST Invoice Available

Pro-Range XKC-Y28-NO DC 24V Non-Contact Liquid Level Sensor

₹849.00 (Inclusive of all taxes)
Out of Stock

The Pro-Range XKC-Y28-NO is a DC 24V non-contact liquid level sensor designed for industrial monitoring systems. It detects liquid levels through container walls without direct contact, making it ideal for corrosive, toxic, or hazardous fluids. The sensor offers adjustable sensitivity and is compatible with PLCs and industrial control panels.

Features

  • Non-contact detection through container walls for safe monitoring of hazardous liquids.
  • Powered by DC 24V, compatible with standard industrial power supplies and PLCs.
  • Adjustable sensitivity for precise level detection across different container materials.
  • Designed for corrosive, toxic, and hazardous fluids like acids, solvents, and oils.
  • Robust construction for industrial environments with high durability and stability.

Out of stock

Description

The Pro-Range XKC-Y28-NO utilizes advanced non-contact sensing technology to detect liquid levels through the walls of non-metallic containers. This principle eliminates the need for direct fluid contact, preventing contamination and sensor degradation when monitoring aggressive chemicals, solvents, or oils. The sensor provides a reliable digital output signal indicating the presence or absence of liquid at the monitored point.

Engineered for industrial reliability, the sensor operates from a DC 24V supply and is built to withstand challenging environmental conditions. Its sealed housing ensures stable performance in applications where precision and safety are critical, such as chemical processing, pharmaceutical manufacturing, and fuel storage systems. The unit requires minimal maintenance and offers straightforward integration into existing monitoring and control architectures.

Key Features

  • Non-Contact Sensing: Detects liquid levels through container walls without physical contact, ideal for hazardous or corrosive media.
  • Industrial 24V DC Power: Operates from a standard DC 24V power supply, ensuring compatibility with industrial PLCs and control systems.
  • Adjustable Sensitivity: Features sensitivity adjustment for optimal performance with various container thicknesses and liquid types.
  • Wide Fluid Compatibility: Suitable for use with acids, solvents, oils, and other aggressive or toxic liquids.
  • Durable Industrial Build: Constructed with a robust housing designed for long-term reliability in industrial environments.
  • Easy Installation & Integration: Simple mounting and wiring for quick deployment into liquid level monitoring systems.

Applications

  • Chemical processing tank level monitoring for acids and solvents.
  • Fuel and oil storage tank level detection in industrial and automotive facilities.
  • Pharmaceutical and biotech fluid level control in non-metallic vessels.
  • Wastewater and treatment plant level sensing for hazardous liquids.
  • Food and beverage industry level monitoring in plastic or glass containers.

Technical Specifications

Manufacturer Part NumberXKC-Y28-NO
Product TypeNon-Contact Liquid Level Sensor
Operating VoltageDC 24V
Sensing PrincipleNon-contact (through-wall)
Container CompatibilityNon-metallic walls
Fluid CompatibilityCorrosive, toxic, hazardous liquids (acids, solvents, oils)
SensitivityAdjustable
Output SignalDigital (NO - Normally Open)
Shipping Weight0.025 kg
Shipping Dimensions (L x W x H)14 × 10 × 3 cm

Frequently Asked Questions

What is the operating voltage for the Pro-Range XKC-Y28-NO sensor?

The sensor operates strictly on a DC 24V power supply. It is designed for compatibility with standard industrial power sources and PLC systems. Ensure your power source provides a stable 24V DC output within the sensor's specified tolerance for reliable operation.

Can this sensor detect liquid through any container material?

No, the XKC-Y28-NO is designed for non-contact detection specifically through non-metallic container walls, such as plastic, glass, or ceramic. Metallic containers will shield the sensing field and prevent accurate detection. Always verify your container material is compatible before installation.

What types of liquids is this sensor suitable for?

This sensor is ideal for monitoring corrosive, toxic, or otherwise hazardous liquids where direct contact is undesirable. This includes acids, solvents, oils, and aggressive chemicals. Its non-contact principle prevents sensor contamination and degradation from the monitored fluid.

How do I adjust the sensor's sensitivity?

The sensor features an adjustable sensitivity control, typically via a potentiometer or DIP switch on the unit. Adjustment is necessary to optimize detection for specific container wall thicknesses and liquid properties. Refer to the product datasheet for detailed calibration procedures for your specific application.

What is the output signal of the XKC-Y28-NO sensor?

The 'NO' in the model number indicates a Normally Open digital output. The sensor's output switch closes (or provides a signal) when liquid is detected at the sensing point. This digital signal can be directly connected to PLC digital inputs, relays, or indicator lights for system integration.

Package Includes

  • 1 x Pro-Range XKC-Y28-NO DC 24V Non-Contact Liquid Level Sensor

Additional Information

Weight 0.025 kg
Dimensions 14 × 10 × 3 cm