SKU: SENS-0315
📋 GST Invoice Available

Desun Uniwill DS510 pH Sensor, 0-14pH, RS485 Output, MODBUS

₹22,259.00 (Inclusive of all taxes)
Out of Stock

The Desun Uniwill DS510 is an industrial-grade digital pH sensor with a 0-14pH measurement range and RS485 MODBUS output, designed for integration into PLC, SCADA, and IoT-based water quality monitoring systems. It features automatic temperature compensation and a robust SS316/POM housing for long-term stability in demanding environments.

Features

  • High-precision pH measurement with ±0.01 pH accuracy and a 0-14pH range.
  • RS485 digital interface with MODBUS protocol for direct PLC and industrial controller integration.
  • Built-in temperature sensor provides automatic temperature compensation (ATC) for reliable readings.
  • IP68-rated, corrosion-resistant housing constructed from SS316 stainless steel and POM plastic.
  • Fast response time under 30 seconds and low power consumption (<50mA at 6-12V DC).

Out of stock

Description

The Desun Uniwill DS510 pH sensor utilizes a high-quality industrial wire electrode with a flat front-end design for easy cleaning and maintenance. Its digital RS485 output transmits stable, noise-immune pH and temperature data via the MODBUS protocol, eliminating analog signal degradation common in long cable runs.

Engineered for continuous online monitoring, the sensor’s SS316 stainless steel and POM construction provides exceptional corrosion resistance against a wide range of chemicals. The integrated temperature sensor enables precise automatic temperature compensation (ATC), ensuring measurement accuracy across its 0–50°C operating range, making it suitable for harsh industrial and environmental applications.

Key Features

  • Industrial-Grade Digital Output: RS485 interface with MODBUS RTU protocol ensures reliable, long-distance communication with PLCs, DCS, and data loggers.
  • High-Accuracy Sensing: Delivers ±0.01 pH precision with a broad 0-14 pH measurement span for comprehensive water analysis.
  • Automatic Temperature Compensation (ATC): Built-in temperature sensor corrects pH readings in real-time for consistent accuracy.
  • Robust Environmental Protection: IP68 waterproof rating and corrosion-resistant SS316/POM housing guarantee durability in submerged or wet conditions.
  • Optimized Electrode Design: Flat-front industrial wire electrode facilitates easy cleaning and reduces fouling for stable long-term performance.
  • Fast System Response: Achieves a rapid stabilization time of less than 30 seconds for dynamic process monitoring.
  • Wide Operating Voltage: Supports 6-12V DC supply with low current draw (<50mA), compatible with standard industrial power sources.
  • High Electrical Isolation: Features dielectric strength >500V DC and insulation resistance ≥20 MOhm for safe operation in electrically noisy environments.

Applications

  • Continuous pH monitoring in industrial wastewater treatment and effluent control systems.
  • Water quality analysis for environmental monitoring stations, rivers, and lakes.
  • Process control in chemical manufacturing, pharmaceutical production, and food & beverage industries.
  • Aquaculture and hydroponic system management for nutrient solution pH regulation.
  • Integration into IoT-based smart agriculture and precision irrigation networks.

Technical Specifications

Model NumberDS510
Measurement Range0 – 14 pH
Accuracy±0.01 pH
Response Time< 30 seconds
Output InterfaceRS485 (MODBUS Protocol)
Supply Voltage6 – 12 V DC
Current Consumption< 50 mA
Operating Temperature0 – 50 °C
Protection RatingIP68
Housing MaterialPOM + SS316 Stainless Steel
Cable Length5 meters
Dimensions (L x Ø)168 mm x 26 mm
Weight1200 g
Dielectric Strength> 500 V DC
Insulation Resistance≥ 20 MOhm

Frequently Asked Questions

What is the communication protocol and wiring for the DS510 pH sensor?

The DS510 uses a standard RS485 interface communicating via the MODBUS RTU protocol. It typically requires a 2-wire connection (A and B data lines) plus power (6-12V DC and GND). You must connect it to an RS485-to-USB converter or a PLC's RS485 port and configure your software with the correct MODBUS register addresses for pH and temperature data.

How do I calibrate the DS510 pH sensor, and does it require maintenance?

Calibration is performed using standard pH buffer solutions (e.g., pH 4.01, 7.00, 10.01) via MODBUS commands sent to the sensor's calibration registers. The flat-front industrial electrode design allows for easy cleaning; periodic rinsing with distilled water and gentle cleaning with a soft brush is recommended to prevent biofilm or scaling buildup for long-term accuracy.

What is the maximum cable length for reliable RS485 communication?

The sensor includes a 5-meter integrated cable. For RS485 networks, you can extend the total bus length up to 1200 meters reliably by using proper shielded twisted-pair cable and terminating the bus with 120-ohm resistors at both ends. Ensure the power supply voltage remains within 6-12V DC over the extended cable run to account for voltage drop.

Can the DS510 be used in seawater or highly corrosive chemical environments?

Yes, its SS316 stainless steel and POM plastic housing provides excellent corrosion resistance against many chemicals, including mild acids, alkalis, and seawater. However, for prolonged exposure to highly concentrated acids or specific aggressive chemicals, verifying material compatibility against the SS316 and POM chemical resistance charts is advised.

Package Includes

  • 1 x Desun Uniwill DS510 pH Sensor (with integrated 5m cable)

Additional Information

Weight 1.2 kg
Dimensions 16.8 × 2.6 cm