SKU: SENS-0596
📋 GST Invoice Available

Asair AFD4040 Series Vortex Liquid Flowmeter - PPS & SUS304 Stainless Steel, G/RC/NPT Thread

₹7,209.00 (Inclusive of all taxes)
Out of Stock

The Asair AFD4040 Series is a vortex flow sensor designed for precise liquid flow measurement in industrial and commercial systems, compatible with PLCs and DAQ systems via 4-20mA or RS485 Modbus output.

Features

  • Operates on the Von Karman vortex principle for stable, drift-free flow measurement.
  • Constructed from durable PPS and SUS304 stainless steel for chemical and pressure resistance.
  • Offers multiple flow ranges (2-16, 5-40, 10-100 L/min) and thread options (G, RC, NPT).
  • Provides 4-20mA analog or RS485 Modbus digital output for flexible system integration.
  • Rated for high-pressure environments with a maximum pressure of 16 bar.

Out of stock

Description

The Asair AFD4040 Series Vortex Liquid Flowmeter utilizes the Von Karman vortex street principle. As fluid flows past a bluff body (spoiler column), alternating vortices are shed at a frequency proportional to the flow velocity. An internal piezoelectric or capacitive sensor detects this frequency, which the onboard chip converts into a precise volumetric flow rate signal.

Engineered for demanding liquid process control, the sensor’s PPS polymer and SUS304 stainless steel construction ensures long-term durability against corrosion, scaling, and high-pressure surges up to 16 bar. Its fast response time and immunity to drift make it suitable for continuous monitoring in HVAC, water treatment, chemical dosing, and industrial cooling systems.

Key Features

  • Vortex Shedding Principle: Provides a digital-frequency output directly proportional to flow rate, ensuring high repeatability and no zero drift.
  • Robust Mechanical Design: Housing made from chemical-resistant PPS and corrosion-resistant SUS304 stainless steel for extended service life in harsh liquids.
  • Wide Operational Envelope: Functions in ambient temperatures from -10 to 60°C and handles liquid temperatures from 0 to 90°C.
  • Flexible Output & Power: Supports industry-standard 4-20mA analog or RS485 Modbus digital communication, powered by 18-28 VDC.
  • High-Pressure Rating: Withstands a maximum working pressure of 16 bar (10 bar nominal), suitable for pressurized pipeline applications.
  • Configurable Installation: Available with G (parallel), RC (tapered), or NPT pipe threads for global plumbing compatibility.

Applications

  • Precise water flow monitoring and control in industrial cooling towers and chillers.
  • Chemical injection and dosing systems requiring stable, contamination-resistant measurement.
  • HVAC hydronic systems for balancing and energy management in commercial buildings.
  • Water treatment plants for monitoring filter backwash rates and chemical feed flows.
  • Process control in food & beverage or pharmaceutical manufacturing lines.

Technical Specifications

Manufacturer Part NumberAFD4040 Series
BrandAsair
Measurement PrincipleVon Karman Vortex Shedding
Flow Range Options2–16 L/min, 5–40 L/min, 10–100 L/min
Flow Accuracy±1.5% of reading (typical)
Output SignalThree-wire: 4–20 mA, RS485 (Modbus), or NPN open collector
Supply Voltage18–28 VDC
Max Pressure16 bar
Operating Ambient Temperature-10 to 60 °C
Operating Liquid Temperature0 to 90 °C
Connector Thread TypeG, RC, or NPT
Housing MaterialPPS Polymer & SUS304 Stainless Steel

Frequently Asked Questions

What is the operating voltage range for the AFD4040 flowmeter?

The AFD4040 requires a 18–28 VDC power supply. This range is standard for industrial 24V DC systems and ensures stable operation of its internal signal conditioning circuitry for both 4-20mA and RS485 output modes.

What types of output signals does this sensor support?

It supports a three-wire configuration with your choice of 4-20mA analog current output or RS485 digital communication (typically using Modbus RTU protocol). An NPN open-collector pulse output variant may also be available for simple frequency counting.

Can this sensor handle hot water or other high-temperature liquids?

Yes. The AFD4040 is rated for liquid temperatures from 0°C up to 90°C, making it suitable for hot water lines, heat transfer fluids, and various industrial process liquids within its specified pressure limit of 16 bar.

What pipe thread connections are available?

The sensor is offered with a choice of standard pipe threads: G (parallel/BSPP), RC (tapered/BSPT), or NPT (American National Pipe Taper). You must specify the required thread type during selection to ensure proper installation.

How do I interface the RS485 output with a PLC or data logger?

Connect the sensor's RS485 wires (A, B, and ground) to your controller's RS485 port. You will need to configure your software with the correct Modbus RTU parameters (baud rate, parity, slave address) as defined in the sensor's datasheet to read flow rate registers.

Package Includes

  • 1 x Asair AFD4040 Series Vortex Liquid Flowmeter

Additional Information

Weight 0.62 kg
Dimensions 17 × 17 × 8 cm