The DFRobot Gravity Analog pH Sensor Pro Kit V2 is an industrial-grade pH measurement system designed for continuous online monitoring in aqueous solutions. It features a 3.3-5.5V wide voltage input compatible with Arduino, Raspberry Pi, and other 5V/3.3V logic controllers, delivering a stable 0-3.0V analog output corresponding to a 0-14 pH range.

Features

  • Industrial-grade pH probe with sensitive low-impedance glass membrane for fast response and thermal stability.
  • Onboard signal conditioning provides hardware-filtered, low-jitter 0-3.0V analog output.
  • Wide 3.3-5.5V supply voltage compatible with 5V and 3.3V microcontroller systems (Arduino, ESP32, Raspberry Pi).
  • Software library supports two-point calibration with automatic recognition of 4.0 and 7.0 pH standard buffer solutions.
  • Includes 500cm cable, BNC connector, and plug-and-play Gravity PH2.0-3P interface for solder-free setup.

Out of stock

Description

The DFRobot Gravity Analog pH Sensor Pro Kit V2 employs an industrial-grade combination pH electrode based on a sensitive glass membrane and an Ag/AgCl gel electrolyte reference system. This design ensures low alkali error, excellent reproducibility, and stable half-cell potential for accurate, long-term measurements in diverse aqueous environments from 0 to 60°C. The integrated signal conversion board conditions the electrode’s millivolt-level output to a clean 0-3.0V analog signal, minimizing noise and jitter for reliable ADC readings.

Engineered for 24/7 online monitoring, the probe features a PTFE reference junction resistant to clogging, enhancing its longevity in demanding applications like aquaculture, hydroponics, and wastewater treatment. The kit’s modular design, standardized Gravity connector, and comprehensive software library enable rapid system integration and calibration, making it suitable for both prototyping and deployed industrial sensing nodes.

Key Features

  • Industrial-grade pH electrode with low-impedance glass membrane and Ag/AgCl reference.
  • Hardware-filtered 0-3.0V analog output ensures stable, low-noise readings for precise ADC conversion.
  • Wide operating voltage range (3.3-5.5V DC) supports seamless integration with 5V Arduino and 3.3V Raspberry Pi/ESP32 platforms.
  • Advanced software library facilitates two-point calibration and automatic buffer solution identification.
  • Robust construction with PTFE junction and 500cm shielded cable for long-term, continuous deployment.
  • Plug-and-play Gravity PH2.0-3P and BNC connectors eliminate soldering and simplify mechanical assembly.
  • High-accuracy measurement: ±0.1 pH at 25°C across the full 0-14 pH range.
  • Optimized performance-to-cost ratio for professional water quality monitoring systems.

Applications

  • Continuous pH monitoring in aquaculture tanks and recirculating aquaculture systems (RAS).
  • Nutrient solution management and control in hydroponic and aquaponic growing systems.
  • Industrial wastewater treatment process monitoring and effluent quality compliance testing.
  • Environmental water quality assessment in lakes, rivers, and reservoirs.
  • Laboratory-grade pH measurement for chemical process control and educational setups.

Technical Specifications

Measurement Range0 - 14 pH
Accuracy±0.1 pH (at 25°C)
Output Signal0 - 3.0V Analog
Supply Voltage3.3 - 5.5 VDC
Probe TypeIndustrial Grade Combination Electrode
Probe ConnectorBNC
Board ConnectorGravity PH2.0-3P
Operating Temperature0°C to +60°C
Response Time< 1 minute (typical)
Electrode LifetimeApprox. 0.5 years (dependent on water quality)
Cable Length500 cm
Signal Board Dimensions42 mm x 32 mm

Frequently Asked Questions

What is the output signal type and range of this pH sensor kit?

The sensor kit provides a 0 to 3.0V analog output voltage, linearly corresponding to the 0-14 pH measurement range. This standard analog signal can be directly read by the ADC (Analog-to-Digital Converter) pin of any microcontroller, such as an Arduino or Raspberry Pi, for straightforward integration and calibration.

What power supply voltage is required, and is it compatible with 3.3V systems?

The onboard voltage regulator accepts a wide input range of 3.3 to 5.5V DC, making it fully compatible with both 5V systems (like most Arduinos) and 3.3V logic platforms (like ESP32, Raspberry Pi, and STM32). Simply connect the red wire to your board's 3.3V or 5V pin, the black wire to GND, and the blue wire to an analog input pin.

How do I calibrate the sensor, and what buffer solutions are needed?

Calibration uses a two-point method supported by the DFRobot software library. You will need standard pH buffer solutions, typically pH 4.01 and pH 7.00. The library can automatically identify these buffers. Follow the calibration procedure by immersing the probe in each solution sequentially and recording the stable ADC values to establish an accurate calibration curve.

What is the expected lifespan of the industrial pH probe?

The industrial-grade combination electrode has a typical functional lifespan of approximately 6 months (0.5 years) under continuous use, though this is highly dependent on the application's water quality, temperature, and maintenance. The PTFE reference junction resists clogging to prolong life. For optimal performance, regular cleaning and storage in a proper storage solution or pH 4 buffer is recommended.

Package Includes

  • 1 x Industrial Grade pH Probe (BNC connector, 500cm cable)
  • 1 x pH Signal Conversion Board V2 (Gravity PH2.0-3P connector)
  • 1 x Gravity Analog Sensor Cable (PH2.0-3P to Dupont)
  • 2 x Waterproof Gasket
  • 1 x Screw Cap for BNC Connector
  • 4 x M3 x 10mm Nylon Pillar
  • 8 x M3 x 5mm Screws