SKU: SENS-1358
📋 GST Invoice Available

Pro-Range XKC-Y28-NC-DC 24V Non-Contact Liquid Level Sensor

₹569.00 (Inclusive of all taxes)
Out of Stock

The Pro-Range XKC-Y28-NC-DC is a 24V non-contact liquid level sensor designed for industrial monitoring systems. It detects liquid levels through container walls, making it ideal for use with corrosive, toxic, or hazardous fluids without direct contact. The sensor is compatible with PLCs, industrial controllers, and 24V DC automation systems.

Features

  • Non-contact capacitive sensing through container walls for safe fluid detection.
  • 24V DC industrial power supply for integration with PLCs and automation panels.
  • Adjustable sensitivity for precise detection across various container materials and liquid types.
  • Robust construction for use with corrosive, toxic, or hazardous liquids like acids and solvents.
  • Easy installation with minimal maintenance requirements for industrial environments.

Out of stock

Description

The Pro-Range XKC-Y28-NC-DC sensor operates on a capacitive sensing principle, detecting changes in dielectric constant caused by the presence of liquid. This non-contact method allows it to sense levels through the walls of non-metallic containers, eliminating the risk of contamination or sensor corrosion from aggressive media. The unit is powered by a standard 24V DC supply common in industrial control cabinets.

Engineered for stability in challenging environments, the sensor provides reliable binary (on/off) level detection. Its output is designed to interface directly with programmable logic controllers (PLCs), relay modules, or digital input cards, facilitating integration into automated liquid management, tank monitoring, and process safety systems.

Key Features

  • Non-contact capacitive sensing technology for safe, contamination-free operation.
  • 24V DC power input compatible with standard industrial control voltages.
  • User-adjustable sensitivity to optimize detection for specific container and liquid properties.
  • Durable housing designed for reliable performance in industrial environments.
  • Outputs a clean digital switch signal for direct PLC or controller integration.
  • Ideal for monitoring acids, solvents, oils, and other hazardous or corrosive liquids.
  • Simple mounting and wiring for quick deployment into existing systems.
  • High-value build offering long-term reliability with minimal maintenance.

Applications

  • Level monitoring in chemical storage tanks containing acids or solvents.
  • Overfill/underfill prevention in industrial process tanks with hazardous fluids.
  • Tank level detection in water treatment and pharmaceutical manufacturing.
  • Liquid presence sensing in pipelines and dispensing systems for oils and fuels.
  • Safety interlock systems for equipment requiring liquid level verification.

Technical Specifications

Item TypeLiquid Level Sensor
Model NumberXKC-Y28-NC
Operating VoltageDC 24V
Sensing PrincipleNon-contact Capacitive
Detection MethodThrough-wall (non-metallic containers)
Output SignalDigital Switch (High/Low)
Application MediaCorrosive, Toxic, Hazardous Liquids (Acids, Solvents, Oils)
SensitivityAdjustable

Frequently Asked Questions

What is the operating voltage for this Pro-Range liquid level sensor?

This sensor is designed for a 24V DC power supply, which is the standard voltage used in many industrial control panels and PLC systems. Ensure your power source is stable and within the specified range for reliable operation.

How does the non-contact detection work, and what materials can it sense through?

The sensor uses capacitive sensing to detect changes in the dielectric constant caused by the presence of liquid. It can sense through the walls of non-metallic containers such as plastic, glass, or fiberglass. It cannot detect through conductive materials like metal.

Can this sensor be used with corrosive or hazardous liquids?

Yes, a primary advantage of this non-contact design is that the sensor does not physically touch the liquid. This makes it perfectly suited for monitoring corrosive, toxic, or hazardous media like acids, solvents, and oils, preventing sensor degradation and contamination.

How do I adjust the sensor's sensitivity?

The sensor features an adjustable sensitivity potentiometer, typically located on the housing. By turning this adjustment, you can fine-tune the detection threshold to account for different container wall thicknesses, material types, and the specific dielectric properties of the liquid being monitored.

What type of output signal does this sensor provide?

The XKC-Y28-NC provides a digital switch output (typically an NPN or PNP open-collector transistor output, check datasheet). This output changes state (High/Low) based on the presence or absence of liquid, making it directly compatible with PLC digital inputs, relays, or microcontroller GPIO pins.

Package Includes

  • 1 x Pro-Range XKC-Y28-NC-DC 24V Non-Contact Liquid Level Sensor

Additional Information

Weight 0.025 kg
Dimensions 14 × 10 × 3 cm