SKU: SENS-0909
📋 GST Invoice Available

Asair AO-08 Medical Oxygen Sensor Module

₹2,659.00 (Inclusive of all taxes)
Out of Stock

The Asair AO-08 is a high-precision electrochemical medical oxygen sensor module designed for integration into oxygen analyzers and life-support equipment. It provides a linear 9–13 mV output signal in ambient air (21% O₂) across a 0–100% oxygen concentration range, requiring no external power supply for operation.

Features

  • Electrochemical sensing cell for 0–100% oxygen concentration measurement.
  • Linear output signal (9–13 mV in 21% Oâ‚‚) with no external power required.
  • Fast response time of less than 15 seconds for real-time monitoring.
  • Integrated temperature compensation for stable readings from 0°C to 40°C.
  • Designed for medical applications including ventilators and oxygen concentrators, compliant with ISO 80601-2-55.

Out of stock

Description

The AO-08 Medical Oxygen Sensor from Asair (Aosong Electronics) utilizes an advanced electrochemical cell to deliver precise and reliable measurement of oxygen concentration in breathing gas mixtures. Its molded body is specifically engineered for medical environments, ensuring long service life and resistance to interference.

This sensor generates a millivolt-level output proportional to the partial pressure of oxygen, featuring built-in temperature compensation to maintain accuracy across its specified operating range of 0°C to 50°C and 0.5 to 2.0 bar pressure. The fast response time supports critical applications where rapid feedback on oxygen levels is essential.

Key Features

  • Medical-grade electrochemical oxygen sensing element.
  • Linear voltage output across the full 0% to 100% measurement range.
  • Self-powered operation; generates its own signal without an external supply.
  • Integrated temperature compensation minimizes error (<2% Oâ‚‚ equivalent from 0–40°C).
  • Excellent long-term signal stability and repeatability.
  • Fast response time under 15 seconds for dynamic gas monitoring.
  • Robust design offers high resistance to electromagnetic and environmental interference.
  • Compliant with medical device standard ISO 80601-2-55 for critical care applications.

Applications

  • Oxygen concentration sensing in medical ventilators and anesthesia machines.
  • Primary sensing component in stationary or portable oxygen analyzers.
  • Feedback control for oxygen concentrators and gas blending systems.
  • Environmental monitoring in neonatal incubators and hyperbaric chambers.
  • Industrial safety systems for oxygen level monitoring in confined spaces.

Technical Specifications

Item TypeOxygen Sensor
Output Signal9 mV to 13 mV in 21% Oâ‚‚
Measurement Range0 – 100 Vol.% O₂
Temperature Compensation Error<2% O₂ equivalent (0℃–40℃)
Response Time (T90)<15 s
Operating Temperature0℃ to +50℃
Pressure Range0.5 Bar to 2.0 Bar
Operating Humidity0% to 99% RH (non-condensing)
ComplianceISO 80601-2-55

Frequently Asked Questions

Does the AO-08 sensor require an external power supply to operate?

No, the AO-08 is a self-powered electrochemical sensor. It generates its own millivolt-level output signal (9–13 mV in 21% oxygen) proportional to the oxygen partial pressure, requiring no external power supply for its basic sensing function. However, this signal will typically need to be conditioned and amplified by an external analyzer circuit.

What is the output signal format and how do I interface with it?

The sensor provides a linear analog voltage output relative to oxygen concentration. In ambient air (21% Oâ‚‚), the output is typically between 9 and 13 mV. This low-level signal must be connected to a high-impedance input of a dedicated oxygen analyzer board or a precision instrumentation amplifier circuit to be read accurately by a microcontroller or data acquisition system.

What are the key environmental limits for operating this sensor?

The AO-08 is rated for an operating temperature range of 0°C to 50°C and a pressure range of 0.5 to 2.0 bar. It includes temperature compensation to maintain accuracy within 2% O₂ equivalent between 0°C and 40°C. The sensor can operate in 0–99% relative humidity, but condensation must be avoided to prevent damage.

Is this sensor suitable for use in medical ventilators?

Yes, the Asair AO-08 is specifically designed as a sensing component for medical oxygen analyzers used in life-support equipment like ventilators and anesthesia machines. Its design and performance comply with the medical device standard ISO 80601-2-55, ensuring it meets the requirements for accuracy, reliability, and safety in critical care applications.

Package Includes

  • 1 x Asair AO-08 Medical Oxygen Sensor Module

Additional Information

Weight 0.048 kg
Dimensions 7.5 × 8 × 4 cm