SKU: SENS-0848
📋 GST Invoice Available

Winsen ZE21-H2 Hydrogen Gas Detection Module - UART Output, 0-20000ppm Range

₹2,259.00 (Inclusive of all taxes)
Out of Stock

The Winsen ZE21-H2 is a specialized electrochemical hydrogen gas detection module designed for vehicle Battery Management Systems (BMS) and other safety-critical applications. It provides digital UART (3.3V TTL) output for easy integration with microcontrollers, industrial PLCs, and data loggers, offering precise monitoring of hydrogen concentrations from 0 to 20,000 ppm.

Features

  • Electrochemical sensing principle for high selectivity and stability.
  • Digital UART (3.3V TTL) and analog voltage output options.
  • Wide detection range of 0 to 20,000 ppm with 50 ppm resolution.
  • Built-in temperature sensor for automatic temperature compensation.
  • Designed for harsh environments with an operating range of -30°C to 65°C.

Out of stock

Description

The ZE21-H2 module leverages mature electrochemical detection technology to provide reliable and selective monitoring of hydrogen gas. Its miniaturized design incorporates sophisticated signal conditioning circuitry that ensures stable output and high resistance to common interfering gases like carbon dioxide, making it suitable for complex industrial atmospheres.

Featuring both digital serial communication and an analog voltage output, the module offers flexible integration into existing control systems, including automotive BMS, fuel cell monitoring, and laboratory safety setups. The built-in temperature compensation enhances accuracy across its full operating temperature range, while its low power consumption supports continuous deployment in battery-powered or energy-conscious applications.

Key Features

  • Electrochemical sensor cell with high sensitivity and selectivity for hydrogen.
  • Dual output: UART (3.3V TTL logic) and analog voltage for maximum compatibility.
  • Integrated temperature sensor for real-time environmental compensation.
  • Fast response time (T90 ≤ 5 seconds) for rapid leak detection.
  • Robust construction rated for operation from -30°C to 65°C and 15-90% RH.
  • Optimized performance-to-cost ratio with a typical sensor life of 3-5 years in air.
  • Low power consumption suitable for portable and vehicle-integrated systems.
  • Compact form factor for easy installation in space-constrained environments.

Applications

  • Vehicle Battery Management Systems (BMS) for hydrogen fuel cell leak detection.
  • Safety monitoring in hydrogen refueling stations and storage facilities.
  • Industrial process control and leak detection in chemical manufacturing.
  • Laboratory gas analysis and environmental safety monitoring.
  • Integration into portable gas detectors for emergency response teams.

Technical Specifications

Item TypeGas Sensor Module
Model NumberZE21-H2
Detection GasHydrogen (H2)
Interfering GasesCarbon dioxide, etc.
Output InterfaceUART (3.3V TTL), Analog Voltage
Operating Voltage5–10V DC
Preheat Time40 seconds
Response Time (T90)≤ 5 seconds
Recovery Time≤ 60 seconds
Detecting Range0 – 20,000 ppm
Resolution50 ppm
Operating Temperature-30°C to 65°C
Operating Humidity15% RH to 90% RH (non-condensing)
Storage Temperature30°C to 65°C
Life Cycle3–5 years (in air)

Frequently Asked Questions

What is the output interface of the Winsen ZE21-H2 module?

The module provides a digital UART serial interface operating at 3.3V TTL logic levels, allowing direct connection to microcontrollers like Arduino, ESP32, or Raspberry Pi. It also offers an analog voltage output for simpler integration with analog-to-digital converters (ADCs) in data acquisition systems.

What is the operating voltage range for this hydrogen sensor?

The ZE21-H2 module requires a DC supply voltage between 5V and 10V. It is crucial to stay within this range to ensure proper sensor heater operation and signal conditioning circuit functionality. A stable, regulated power source is recommended for accurate measurements.

How long does the sensor need to stabilize before use?

The module requires a preheat time of approximately 40 seconds after power-on to stabilize the electrochemical cell and internal circuitry. After this period, the sensor is ready for accurate measurement. The fast response time (T90 ≤ 5 seconds) enables rapid detection of hydrogen concentration changes.

What is the typical lifespan of the ZE21-H2 sensor?

The electrochemical sensor element has a typical operational lifespan of 3 to 5 years when used in normal atmospheric conditions. Lifespan can be affected by exposure to extreme temperatures, high concentrations of target gas, or contaminating substances. It is considered a consumable component.

Can this sensor be used outdoors or in cold environments?

Yes, the module is rated for operation in temperatures from -30°C to 65°C and humidity from 15% to 90% RH (non-condensing), making it suitable for many outdoor and industrial applications. The built-in temperature sensor provides compensation, but physical protection from direct rain, icing, or condensation is advised.

Package Includes

  • 1 x Winsen ZE21-H2 Hydrogen Gas Detection Module

Additional Information

Weight 0.01 kg
Dimensions 7 × 4 × 2 cm