SKU: SENS-0894
📋 GST Invoice Available

Winsen ME4-H2 Hydrogen Gas Sensor Module - 0-1000ppm Electrochemical

₹13,150.00 (Inclusive of all taxes)
Out of Stock

The Winsen ME4-H2 is an electrochemical hydrogen gas sensor module designed for industrial and environmental monitoring applications. It provides a linear current output proportional to H2 concentration from 0 to 1000ppm, with a resolution of 1ppm and a T90 response time of ≤30 seconds.

Features

  • Electrochemical sensing principle for hydrogen (H2) detection with high selectivity.
  • Measurement range of 0 to 1000ppm H2 with a maximum range of 2000ppm.
  • Sensitivity of (0.03±0.01) µA/ppm, providing a linear current output signal.
  • Fast response time (T90) of ≤30 seconds and a resolution of 1ppm.
  • Designed for industrial environments with an operating temperature range of -20°C to 50°C.

Out of stock

Description

The Winsen ME4-H2 hydrogen gas sensor employs a constant potential electrolysis (electrochemical) working principle. Oxidation and reduction reactions occur at the working and counter electrodes, respectively, generating a current directly proportional to the concentration of hydrogen gas present. This current signal is measured to determine the precise gas concentration.

Engineered for reliability in demanding conditions, the sensor features excellent repeatability (<2% output value) and long-term stability (<2% per month). It operates effectively across a broad humidity range of 15% to 90% RH (non-condensing) and at standard atmospheric pressure ±10%. The module is designed for easy integration into industrial safety systems, environmental monitoring stations, and research setups requiring accurate H2 level detection.

Key Features

  • Electrochemical Sensing Cell: Utilizes a fuel cell-based constant potential electrolysis method for precise and selective hydrogen detection.
  • Linear Current Output: Provides a 4-20mA compatible signal with sensitivity of (0.03±0.01) µA/ppm for straightforward signal conditioning.
  • High Stability & Repeatability: Offers excellent measurement consistency with <2% repeatability and <2% per month long-term drift.
  • Robust Environmental Tolerance: Operates from -20°C to 50°C and 15-90% RH, suitable for varied industrial settings.
  • Fast Dynamic Response: Achieves 90% of final reading (T90) within 30 seconds for timely gas concentration alerts.
  • Recommended Load Resistor: Includes a specified 10Ω load resistance for optimal signal measurement and sensor performance.

Applications

  • Industrial Hydrogen Leak Detection: Monitoring for H2 leaks in chemical processing plants, refineries, and semiconductor fabrication cleanrooms.
  • Fuel Cell System Safety: Integrated safety monitoring within hydrogen fuel cell stacks and hydrogen storage facilities.
  • Laboratory & Research Analysis: Precise measurement of hydrogen concentration in gas mixing experiments and analytical instrumentation.
  • Environmental Air Quality Monitoring: Deployed in stationary or portable stations to track ambient hydrogen levels near industrial sites.

Technical Specifications

Detection GasHydrogen (H2)
Detection Range0–1000 ppm
Maximum Range2000 ppm
Sensitivity(0.03 ± 0.01) µA/ppm
Resolution1 ppm
Response Time (T90)≤ 30 seconds
Recommended Load Resistance10 Ω
Repeatability< 2% of output value
Long-term Stability< 2% per month
Output LinearityLinear
Zero Drift≤ 10 ppm (-20°C to 40°C)
Operating Temperature-20°C to 50°C
Operating Humidity15% to 90% RH (non-condensing)
Pressure RangeStandard atmospheric pressure ±10%
Sensor Life2 years

Frequently Asked Questions

What is the output signal of the Winsen ME4-H2 sensor?

The ME4-H2 provides a linear current output proportional to hydrogen concentration. Its sensitivity is (0.03±0.01) µA/ppm. This current signal can be converted to a voltage using the recommended 10Ω load resistor for easy reading by microcontrollers (Arduino, Raspberry Pi) or industrial PLCs with analog input modules.

What is the operating voltage and how do I power this sensor?

The ME4-H2 is an electrochemical sensor that requires a constant potential applied to its electrodes, typically provided by dedicated potentiostat circuitry or a compatible transmitter board. It is not directly powered by a simple DC voltage. For integration, you will need a supporting circuit or module that provides the correct biasing and signal conditioning for the sensor cell.

How often does the ME4-H2 sensor require calibration?

While the sensor exhibits good long-term stability (<2% drift per month), periodic calibration is recommended for critical applications to maintain accuracy. The manufacturer specifies a sensor life of 2 years. Calibration should be performed using certified hydrogen gas standards at the recommended intervals based on your application's required precision and environmental conditions.

Can this sensor be used outdoors or in high-humidity environments?

Yes, the ME4-H2 is designed for robust environments. It operates across a humidity range of 15% to 90% RH (non-condensing) and temperatures from -20°C to 50°C. For outdoor use, it should be housed in a protective enclosure that prevents direct water ingress (beyond condensation) and allows for proper gas diffusion to the sensor element.

Package Includes

  • 1 x Winsen ME4-H2 Hydrogen Gas Sensor Module

Additional Information

Weight 0.024 kg
Dimensions 6 × 4 × 4 cm