SKU: SENS-0889
📋 GST Invoice Available

Winsen MP-2 Smoke & Propane Gas Sensor Module - Semiconductor Metal Cap

₹209.00 (Inclusive of all taxes)
Out of Stock

The Winsen MP-2 is a semiconductor-type gas sensor module designed for detecting smoke and propane (C3H8) vapors, providing a variable analog output voltage proportional to gas concentration. It is suitable for integration into DIY alarm systems, industrial monitoring, and portable detectors compatible with 3.3V/5V microcontroller platforms like Arduino and Raspberry Pi.

Features

  • Semiconductor sensing element with Al2O3 ceramic substrate for smoke and propane (C3H8) detection
  • Wide detection range from 200 ppm to 10,000 ppm of C3H8
  • Analog output voltage signal (Vs) ranging from 2.5V to 4.0V in 2000ppm C3H8
  • Metal cap encapsulation ensures mechanical durability and stable thermal performance
  • Simple interface requiring only a basic voltage divider or comparator circuit for integration

Out of stock

Description

The Winsen MP-2 sensor utilizes a metal oxide semiconductor (MOS) sensing principle. Its construction features a miniature Al2O3 ceramic plate coated with sensitive material, a built-in heater, and electrodes, all housed within a protective metal cap and base. When exposed to target combustible gases like propane or smoke particulates, the sensor’s conductivity increases proportionally with gas concentration. This change in conductivity can be converted into a corresponding analog output voltage signal using a straightforward external circuit.

Designed for reliability and long-term operation, the MP-2’s planar technology and robust metal encapsulation provide consistent performance across its operational lifespan. It is a core component for creating gas-aware safety systems, requiring minimal supporting electronics to generate a usable alarm or measurement signal.

Key Features

  • Advanced planar semiconductor construction on a subminiature Al2O3 ceramic substrate
  • High sensitivity to propane (C3H8) and smoke across a broad concentration spectrum
  • Robust metal cap and base encapsulation for physical protection and thermal management
  • Linear analog voltage output (Vs) simplifies interfacing with ADCs and comparator ICs
  • Optimized performance-to-cost ratio for volume safety and alarm applications
  • Long operational lifespan with stable baseline conductivity in clean air

Applications

  • Domestic smoke and propane gas leakage alarm systems
  • Industrial safety monitors for workshops and storage facilities handling combustible materials
  • Portable gas detectors for field safety inspections and leak surveys
  • Integrated sensing modules for smart home and building automation safety panels

Technical Specifications

Sensor TypeSemiconductor (Metal Oxide)
Model NumberMP-2
Target GasesPropane (C3H8), Smoke
Detection Range200 ~ 10,000 ppm C3H8
Output SignalAnalog Voltage (Vs)
Output Voltage (in 2000ppm C3H8)2.5V ~ 4.0V
Sensitivity (Ro/Rs in 2000ppm C3H8)≥ 3
Standard EncapsulationMetal Cap
Heater SupplyRequired (typically 5V±0.2V)
Operating PrincipleChange in Metal Oxide Semiconductor Conductivity

Frequently Asked Questions

What is the operating voltage for the Winsen MP-2 sensor's heater?

The MP-2 sensor requires a separate heater supply voltage, typically 5V DC ±0.2V, to bring the metal oxide semiconductor to its optimal operating temperature. The analog sensing output voltage (Vs) is generated independently and should be measured relative to the circuit ground. Always consult the official Winsen datasheet for the precise heater current and voltage requirements.

How do I interface the MP-2 sensor with an Arduino or microcontroller?

Interface the MP-2 by connecting its heater pins to a stable 5V supply. The analog output pin (Vs) connects directly to an analog input pin on a microcontroller like an Arduino. You may need a simple voltage divider or buffer circuit if your MCU operates at 3.3V logic. The sensor output is a DC voltage between 2.5V and 4.0V when exposed to 2000ppm of propane, which can be read using the analogRead() function.

Does the MP-2 sensor require calibration?

Yes, for quantitative measurement, calibration against known gas concentrations is recommended. For binary alarm applications, you can set a threshold voltage on a comparator. The sensor's baseline resistance (Ro) in clean, fresh air should be established first, as its sensitivity is defined as the ratio Ro/Rs (where Rs is resistance in gas). Allow a sufficient warm-up period (several minutes) for the heater to stabilize readings.

Can this sensor detect other gases besides propane and smoke?

The MP-2 is specifically optimized and characterized for propane (C3H8) and smoke. While semiconductor sensors like this can respond to other combustible gases (e.g., methane, butane, alcohol vapors), the sensitivity and cross-interference will differ. For reliable detection of a specific gas, always use a sensor calibrated and specified for that target gas.

Package Includes

  • 1 x Winsen MP-2 Smoke Gas Sensor Module

Additional Information

Weight 0.01 kg
Dimensions 4 × 3 × 1 cm