SKU: SENS-0884
📋 GST Invoice Available

Asair AO-09 Oxygen Sensor Module - Medical Grade, 0-100% O2

₹2,519.00 (Inclusive of all taxes)
Out of Stock

The Asair AO-09 is a medical-grade electrochemical oxygen sensor module designed for precise measurement of oxygen concentration (0-100% O2) in breathing gas mixtures. It features a linear output, integrated temperature compensation, and is engineered for direct integration into medical analyzers, ventilators, and anesthesia equipment.

Features

  • Medical-grade electrochemical oxygen sensor compliant with ISO 80601-2-55.
  • Linear output across the full 0% to 100% oxygen concentration range.
  • Integrated temperature compensation for stable readings from 0°C to 40°C.
  • Fast response time (T90) of less than 15 seconds.
  • White ABS housing with a standard 3P2.5 connector for reliable integration.

Out of stock

Description

The AO-09 sensor from Asair (Aosong Electronics) utilizes a partial pressure electrochemical sensing principle to deliver accurate and reliable oxygen concentration measurements. It is specifically engineered for medical environments, providing a stable millivolt-level output signal proportional to the oxygen partial pressure without requiring an external power supply.

Designed for long life and fast response, the module incorporates built-in temperature compensation to minimize measurement drift across its operating temperature range. Its robust white ABS housing and standardized connector ensure compatibility and durability in critical medical applications such as ventilator control and patient monitoring systems.

Key Features

  • Medical-grade certification meets ISO 80601-2-55 requirements for safety and performance.
  • Linear voltage output from 9 mV to 13 mV in 210 mBar O2, corresponding to 0-100% concentration.
  • Built-in temperature compensation ensures accuracy within <2% O2 equivalent from 0°C to 40°C.
  • Fast response time with T90 < 15 seconds for real-time monitoring and control.
  • High signal stability and anti-interference design for reliable operation in electrically noisy environments.
  • Durable white ABS housing provides a lightweight (36g nominal) and chemically resistant enclosure.
  • Standard 3P2.5 connector simplifies wiring and integration into existing medical device harnesses.
  • Optimized performance-to-cost ratio as a high-value replacement sensor for OEM medical equipment.

Applications

  • Oxygen concentration sensing in medical ventilators and anesthesia delivery systems.
  • Control and feedback component for oxygen concentrators and generators.
  • Patient monitoring within neonatal incubators and critical care environments.
  • Breathing gas mixture analysis in portable and fixed medical oxygen analyzers.
  • Life support equipment requiring precise, reliable, and fast-responding O2 measurement.

Technical Specifications

Item TypeOxygen Sensor Module
Manufacturer Part NumberAO-09
Operating PrinciplePartial Pressure Electrochemical
Measurement Range0 - 100 Vol.% O2
Output Signal9 mV to 13 mV in 210 mBar O2
Response Time (T90)< 15 seconds
Accuracy / ComplianceMeets ISO 80601-2-55 requirements
Temperature Compensation<2% O2 equivalent (0°C to 40°C)
External Load Resistor≥ 10 kΩ
Connector Type3P2.5
Housing MaterialWhite ABS
Weight (Nominal)36 g
OrientationAny

Frequently Asked Questions

What is the output signal of the AO-09 oxygen sensor and how do I interface with it?

The AO-09 provides a linear millivolt-level output, typically between 9 mV and 13 mV when measuring 210 mBar of oxygen pressure. To read this signal, you must connect it to a high-impedance data acquisition system or amplifier with an input impedance of at least 10 kΩ. The sensor uses a standard 3P2.5 connector, and no external power supply is required for the sensing element itself.

Is the AO-09 sensor suitable for use in portable medical devices?

Yes, the AO-09 is well-suited for portable medical devices. Its lightweight ABS housing (36g), any-orientation mounting capability, and lack of an external power requirement make it ideal for integration into portable oxygen concentrators, handheld analyzers, and transport ventilators. The fast response time (<15s T90) ensures timely feedback for patient safety and device control.

How does temperature affect the AO-09 sensor's readings, and is compensation provided?

The sensor features integrated temperature compensation specifically designed for the medical operating range of 0°C to 40°C. This compensation limits the measurement error to less than 2% O2 equivalent across this temperature span. For applications outside this range or requiring ultimate precision, consulting the sensor's detailed performance curves or implementing additional system-level calibration may be necessary.

Package Includes

  • 1 x Asair AO-09 Oxygen Sensor Module

Additional Information

Weight 0.046 kg
Dimensions 7 × 8 × 3 cm