SKU: SENS-0822
📋 GST Invoice Available

MemsFrontier MPY20-A112T Infrared Pyroelectric Gas Sensor (CH4) - TO-39 Package, Dual Channel

₹4,329.00 (Inclusive of all taxes)
Out of Stock

The MemsFrontier MPY20-A112T is a dual-channel infrared pyroelectric gas sensor designed for methane (CH4) detection. It utilizes a lithium tantalate crystal sensing element and operates on a 2-10V supply, making it suitable for integration into industrial safety systems, gas leak detectors, and environmental monitoring equipment.

Features

  • Dual-channel pyroelectric sensor with integrated JFET for methane (CH4) detection.
  • Lithium tantalate (LiTaO3) crystal sensing element ensures high temperature stability and a wide 1-20µm spectral response.
  • TO-39 metal can package provides robust environmental protection for industrial applications.
  • Operates from 2V to 10V DC with a recommended 47kΩ output load for optimal signal conditioning.
  • Features built-in thermal compensation for stable performance across a -40°C to 80°C operating range.

Out of stock

Description

The MPY20-A112T sensor employs the pyroelectric effect, where infrared radiation from target gas molecules (CH4) causes a temperature change in the lithium tantalate crystal, generating a proportional electrical charge. This voltage-mode sensor includes an integrated JFET for impedance conversion, delivering a stable output signal with minimal temperature drift. Its TO-39 hermetic package ensures reliable operation in demanding environments.

Engineered for precision, the sensor offers excellent spectral response consistency and a low thermal time constant of 150 ms for responsive detection. It is designed for direct integration into gas analyzers, safety shut-off systems, and portable leak detectors requiring high sensitivity and long-term stability.

Key Features

  • High-sensitivity dual-element pyroelectric detector for methane gas.
  • Lithium tantalate crystal with a Curie temperature >600°C ensures outstanding thermal stability.
  • Integrated JFET source follower provides low-output impedance and voltage-mode operation.
  • TO-39 metal can package offers mechanical durability and EMI shielding.
  • Wide operating voltage range (2-10V) compatible with various system power rails.
  • Excellent temperature coefficient, with output signal variation as low as 1-2‰ per °C.
  • Broad infrared spectral response from 1µm to 20µm wavelength.
  • Designed for reliable performance in industrial temperature ranges from -40°C to 80°C.

Applications

  • Industrial methane leak detection and safety monitoring systems.
  • Fixed gas detectors for mining, oil & gas, and wastewater treatment facilities.
  • Portable handheld gas analyzers and survey equipment.
  • Residential and commercial natural gas alarm systems.
  • Environmental monitoring and emissions control systems.

Technical Specifications

Manufacturer Part NumberMPY20-A112T
Sensor TypeInfrared Pyroelectric Gas Sensor
Target GasMethane (CH4)
Operating Voltage2 V to 10 V DC (Recommended)
Output ConfigurationDual Channel, Voltage Mode
Integrated ComponentJFET
Sensing ElementLithium Tantalate (LiTaO3) Crystal
Sensing Element Size1.6 mm × 1.6 mm
Window Size2.5 mm × 2.5 mm
Thermal Time Constant150 ms
Feedback Resistance50 GΩ
Recommended Output Load47 kΩ
Operating Temperature-40°C to 80°C
Storage Temperature-40°C to 80°C
Package TypeTO-39 Metal Can

Frequently Asked Questions

What is the recommended operating voltage for the MPY20-A112T sensor?

The MPY20-A112T is designed to operate optimally within a 2V to 10V DC range. Applying voltage within this specification ensures correct biasing of the internal JFET and stable pyroelectric signal output. Exceeding the maximum voltage may damage the sensitive crystal element.

How do I interface with this sensor's output signal?

This sensor operates in voltage mode with an integrated JFET. The output requires an external load resistor, typically 47kΩ, connected between the output pin and ground to convert the current signal to a measurable voltage. The dual-channel design allows for differential measurement to improve noise immunity.

What is the purpose of the lithium tantalate crystal in this sensor?

Lithium tantalate (LiTaO3) is the pyroelectric material that generates an electrical charge when its temperature changes due to absorbed infrared radiation from methane gas. Its high Curie temperature (>600°C) provides exceptional temperature stability, minimizing signal drift across the sensor's -40°C to 80°C operating range.

Is this sensor suitable for outdoor or harsh industrial environments?

Yes, the TO-39 metal can package provides a hermetic seal that protects the sensitive crystal from humidity and contaminants. Combined with its specified operating temperature range of -40°C to 80°C, it is engineered for reliable performance in demanding outdoor and industrial settings such as gas pipelines or processing plants.

Package Includes

  • 1 x MPY20-A112T Infrared Pyroelectric Gas Sensor (CH4)

Additional Information

Weight 0.01 kg
Dimensions 5 × 4 × 3 cm