SKU: IOWC-1496
📋 GST Invoice Available

Wittelb WIN-IO-4DI3DO4AI2AOM I/O Module, 4DI/3DO/4AI/2AO, Modbus RS485

₹7,604.00 (Inclusive of all taxes)
Out of Stock

The Wittelb WIN-IO-4DI3DO4AI2AOM is a DIN-rail mounted industrial I/O module integrating 4 digital inputs, 3 digital outputs, 4 analog inputs, and 2 analog outputs with a Modbus RTU (RS485) interface for seamless integration into PLC and SCADA systems.

Features

  • Comprehensive I/O Mix: Integrates 4 digital inputs (DI), 3 digital outputs (DO), 4 analog inputs (AI), and 2 analog outputs (AO) into a single compact DIN-rail module.
  • Industrial Modbus RTU Protocol: Features an RS485 interface for reliable, long-distance communication with PLCs, HMIs, and SCADA systems using standard Modbus commands.
  • Wide Power Input Range: Operates from 12-24V DC, making it compatible with common industrial power supplies and control cabinets.
  • 10-Bit Resolution Analog Channels: Provides sufficient precision for monitoring sensor voltages (0-10V) and controlling analog actuators in process automation.
  • DIP Switch Configuration: Enables easy setup of device parameters and network addressing without complex software tools.

Out of stock

Description

The Wittelb WIN-IO-4DI3DO4AI2AOM is a robust industrial I/O module engineered for machine automation and process control applications. It consolidates discrete digital signals and analog sensor/actuator interfaces, reducing wiring complexity and cabinet space. The module communicates via a galvanically isolated RS485 serial bus using the Modbus RTU protocol, ensuring compatibility with a vast ecosystem of industrial controllers and software.

Built for 24V DC industrial environments, it offers stable performance across a 0–60°C operating temperature range. The integrated 10-bit ADC and DAC on the analog channels provide reliable measurement and control for variables like temperature, pressure, and flow rates. Its DIN-rail form factor and screw terminal blocks facilitate quick installation and maintenance in control panels.

Key Features

  • Integrated multi-protocol I/O interface combining digital and analog signal conditioning.
  • Modbus RTU over RS485 enables daisy-chaining and network integration with up to 247 devices.
  • DIP switches for easy configuration of baud rate, parity, and slave ID without PC software.
  • Designed for harsh industrial environments with wide operating temperature and voltage tolerance.
  • Screw terminal connectors provide secure, vibration-resistant wiring for sensors and actuators.
  • Fast response time (2ms typical, 6ms max) suitable for real-time control and monitoring loops.
  • Compact DIN-rail mounting saves valuable space inside industrial control cabinets and enclosures.

Applications

  • Industrial Machine Automation: Extend PLC I/O capacity for controlling motors, solenoids, and reading limit switches.
  • Process Control & Monitoring: Interface with analog sensors (temperature, pressure, level) and control valves or variable speed drives.
  • Building Management Systems (BMS): Monitor digital states (door/window contacts) and analog environmental sensors.
  • Data Acquisition (DAQ) Systems: Log analog sensor data and digital event counters via Modbus to a central SCADA or HMI.
  • Remote I/O Expansion: Deploy as a distributed I/O node in large facilities using long-distance RS485 networks.

Technical Specifications

ModelWIN-IO-4DI3DO4AI2AOM-IO
Digital Inputs (DI)4 Channels
Digital Outputs (DO)3 Channels
Analog Inputs (AI)4 Channels, 10-bit
Analog Outputs (AO)2 Channels, 10-bit
Communication ProtocolModbus RTU (RS485)
Power Supply12-24V DC
Operating Current120 mA @ 12V
Operating Temperature0 – 60°C
Response Time2 ms (typical), 6 ms (max)
MountingDIN Rail
Dimensions (LxWxH)110 x 110 x 50 mm

Frequently Asked Questions

How do I configure the Modbus communication parameters on this I/O module?

Use the onboard DIP switches to set the Modbus slave ID (1-247), baud rate (common settings: 9600, 19200, 38400, 57600, 115200), parity (None, Even, Odd), and stop bits. Refer to the datasheet for the specific switch mapping. After power cycling, the module will communicate using the newly set parameters over the RS485 A/B terminals.

What is the voltage range for the analog inputs and outputs?

The analog inputs typically accept a 0-10V DC signal range, converting it with 10-bit resolution (0-1023 counts). The analog outputs also provide a 0-10V DC output signal based on the 10-bit value written via Modbus. Always verify the exact input impedance and output drive capability in the technical datasheet before connecting sensors or actuators.

How do I wire the digital inputs and outputs to my sensors and relays?

Digital inputs are typically designed for 24V DC wetting voltage; connect the sensor's positive to the DI terminal and common negative to the module's COM. Digital outputs are often open-collector or relay-driver types; connect your load (e.g., relay coil) between the DO terminal and a 24V DC supply. Always confirm the sinking/sourcing type and maximum current rating from the datasheet to ensure compatibility.

Can I daisy-chain multiple WIN-IO modules on a single RS485 network?

Yes, you can connect up to 247 modules on one RS485 bus. Wire the RS485 A and B terminals in parallel across all modules, ensuring unique slave IDs set via DIP switches on each unit. Terminate the bus with a 120-ohm resistor at the first and last module to prevent signal reflections, especially for long cable runs exceeding a few hundred meters.

Package Includes

  • 1 x WIN-IO-4DI3DO4AI2AOM-IO Module

Additional Information

Weight 0.25 kg
Dimensions 11 × 11 × 5 cm