SKU: SENS-1604
📋 GST Invoice Available

Generic 50kg Half-Bridge Load Cell Sensor for Body Scales - Alloy Steel, 30cm Cable

₹42.00 (Inclusive of all taxes)
Out of Stock

This 50kg capacity half-bridge load cell sensor is designed for precision weight measurement in body scales and other electronic weighing systems. It features a 1.0±0.1mV/V output sensitivity and is compatible with standard 3-10V DC excitation for integration with instrumentation amplifiers and data acquisition modules.

Features

  • 50 kg capacity with 1.0±0.1 mV/V output sensitivity for precise weight measurement.
  • Half-bridge strain gauge configuration (1000Ω input resistance) requiring external completion resistors for a full Wheatstone bridge.
  • Constructed from durable aluminium alloy with a compact 34 x 34 x 7 mm form factor and a 30cm attached cable.
  • Excellent performance specs: ±0.03% F.S. nonlinearity, ±0.03% F.S. repeatability, and operation from -20°C to 65°C.
  • Designed for parallel use with multiple sensors to increase total system capacity (e.g., 100kg with two, 200kg with four).

Out of stock

Description

This load cell utilizes a half-bridge strain gauge configuration bonded to an aluminium alloy E-shaped beam. When force is applied, the beam deflects, causing a measurable change in the resistance of the strain gauges, which is output as a millivolt-per-volt signal proportional to the load. This half-bridge design requires external completion resistors to form a full Wheatstone bridge circuit, typically implemented using a instrumentation amplifier or dedicated load cell interface module.

The sensor is engineered for high accuracy and stability in electronic weighing applications, featuring low nonlinearity, hysteresis, and creep. Its robust alloy steel construction and wide operating temperature range ensure reliable performance in environments typical for commercial and industrial scales, including platform balances, hopper scales, and belt weighers.

Key Features

  • Half-bridge strain gauge load cell with 50kg rated capacity.
  • High-accuracy specifications: Nonlinearity ±0.03% F.S., Repeatability ±0.03% F.S.
  • Stable 1.0±0.1 mV/V output sensitivity across the operating range.
  • Durable aluminium alloy construction for long-term reliability.
  • Wide operating temperature range from -20°C to +65°C.
  • Designed for parallel configuration to scale system capacity (e.g., 100kg with two cells).
  • Includes a 30cm attached cable for straightforward connection.
  • Compatible with common 5V, 8V, or 3-10V DC excitation sources.

Applications

  • Electronic body weight scales and personal health monitoring devices.
  • Platform scales, bench scales, and industrial floor scales.
  • Hopper and silo weighing systems for inventory control.
  • Belt conveyor weighing and checkweigher applications.
  • Force measurement in DIY robotics and mechatronics projects.

Technical Specifications

Capacity50 kg
Rated Output (Sensitivity)1.0 ± 0.1 mV/V
Nonlinearity± 0.03% F.S.
Repeatability± 0.03% F.S.
Hysteresis± 0.03% F.S.
Creep± 0.15% F.S. / 3min
Zero Balance± 0.3 mV/V
Input Resistance1000 Ω
Output Impedance1000 ± 10% Ω
Insulation Resistance≥ 2000 MΩ
Recommended Excitation Voltage3 - 10 V DC
Operating Temperature Range-20°C to +65°C
Cable Length30 cm
Dimensions (L x W x H)34 x 34 x 7 mm
MaterialAluminium Alloy

Frequently Asked Questions

What is a half-bridge load cell and how do I connect it?

A half-bridge load cell contains two active strain gauges, forming half of a Wheatstone bridge. You must add two external precision resistors to complete the bridge circuit. This is typically done using an instrumentation amplifier (like an INA125 or HX711 module) which provides the completion resistors and amplifies the small mV/V output signal to a usable voltage for an Arduino or PLC.

What is the required excitation voltage for this 50kg load cell?

The sensor is rated for an excitation voltage between 3 and 10 volts DC. A common and stable choice is 5V DC. It is critical to use a stable, low-noise power supply for the excitation, as any variation directly affects the output signal and measurement accuracy.

Can I use multiple sensors together to measure more than 50kg?

Yes, you can connect multiple half-bridge load cells in parallel to increase total system capacity. For example, using two sensors in parallel effectively creates a 100kg system, and four sensors create a 200kg system. All sensors should share a common excitation voltage and their output signals are combined, typically by connecting all signal wires together, before being read by a single amplifier.

What kind of amplifier or module do I need to read this sensor?

You need a dedicated load cell amplifier or ADC module designed for strain gauge signals. Modules like the HX711 (for Arduino) or INA125-based boards are ideal. They provide the necessary bridge completion, high-gain amplification, and analog-to-digital conversion to interface the sensor's millivolt-level output with a microcontroller's digital input.

Package Includes

  • 1 x 50kg Half-Bridge Load Cell Sensor (with 30cm cable).

Additional Information

Weight 0.02 kg
Dimensions 3.4 × 3.4 × 0.7 cm