SKU: SENS-0827
📋 GST Invoice Available

Renke RS-NO2-N01-2-20P Nitrogen Dioxide Sensor Module - 0-20ppm, RS485 Modbus, 10-30V DC

₹20,719.00 (Inclusive of all taxes)
Out of Stock

The Renke RS-NO2-N01-2-20P is a high-precision nitrogen dioxide (NOâ‚‚) gas sensor module featuring an RS485 interface with Modbus-RTU protocol for industrial air quality monitoring. It operates on a wide 10-30V DC supply, offers a 0-20ppm measurement range, and is housed in a wall-mounted, waterproof enclosure suitable for harsh environments.

Features

  • High-precision electrochemical NOâ‚‚ sensor with 0-20ppm range and 0.1ppm resolution.
  • RS485 output with standard Modbus-RTU protocol; address and baud rate configurable.
  • Wide operating voltage range of 10-30V DC with low average power consumption (~0.18W).
  • Wall-mounted, waterproof housing designed for durability in industrial and outdoor applications.
  • Long communication distance up to 2000 meters and stable performance from -20°C to 50°C.

Out of stock

Description

This nitrogen dioxide transmitter utilizes an imported electrochemical sensor core, known for its rapid response and strong anti-interference capabilities. The module’s performance is enhanced through proprietary compensation algorithms and multi-point calibration, resulting in high accuracy (±3% FS), repeatability (±2%), and long-term stability. Its design is tailored for reliable monitoring of NOâ‚‚ concentrations in demanding settings.

The device communicates via an RS485 interface using the industrial-standard Modbus-RTU protocol, allowing for easy integration into Building Management Systems (BMS), Industrial PLCs, and data acquisition systems. The wall-mounted enclosure provides a high level of environmental protection, making it suitable for installation in ventilation ducts, industrial facilities, and outdoor air quality monitoring stations where consistent, accurate gas data is critical.

Key Features

  • Imported electrochemical sensor ensures stable, durable, and interference-resistant NOâ‚‚ detection.
  • Configurable measurement ranges: standard 0-20ppm, optional 0-2000ppm, with custom ranges available.
  • RS485 Modbus-RTU interface supports network addressing and baud rate adjustment for system integration.
  • Wide-voltage 10-30V DC power input accommodates various field power supplies with low energy draw.
  • Optional high-contrast OLED display for local, real-time concentration readout, visible in low light.
  • Robust, wall-mounted waterproof casing offers high ingress protection for harsh environment deployment.
  • Extended communication capability supports cable runs up to 2000 meters for distributed monitoring networks.

Applications

  • Industrial safety and air quality monitoring in manufacturing plants and chemical processing facilities.
  • Ventilation control and indoor air quality (IAQ) assessment in commercial buildings and HVAC systems.
  • Environmental monitoring stations for urban air pollution and roadside NOâ‚‚ concentration tracking.
  • Tunnel and underground parking garage ventilation system control based on real-time gas levels.
  • Integration into smart city and industrial IoT platforms for remote environmental data logging.

Technical Specifications

Manufacturer Part NumberRS-NO2-N01-2-20P
Gas DetectedNitrogen Dioxide (NOâ‚‚)
Measurement Range0 - 20 ppm
Resolution0.1 ppm
Output SignalRS485 (Modbus-RTU Protocol)
Supply Voltage10 - 30 V DC
Average Power Consumption~0.18 W
Operating Temperature-20°C to 50°C
Operating Humidity15 - 90% RH (Non-condensing)
Sensor TypeElectrochemical
Accuracy±3% Full Scale (FS)
Repeatability±2%
Communication DistanceUp to 2000 meters
HousingWall-mounted, Waterproof Enclosure

Frequently Asked Questions

What is the output interface and communication protocol of this NOâ‚‚ sensor?

The sensor provides an RS485 digital output and uses the standard Modbus-RTU communication protocol. This allows for easy daisy-chaining and integration with PLCs, SCADA systems, and data loggers. The Modbus address and baud rate are configurable to suit your network requirements.

What power supply does this module require, and what is its power consumption?

It operates on a wide-range DC input of 10 to 30 volts, making it compatible with common 12V or 24V industrial power supplies. The average power consumption is very low, approximately 0.18 watts, ensuring minimal load on the power source.

Is this sensor suitable for outdoor or harsh environment installation?

Yes, the sensor is housed in a wall-mounted, waterproof enclosure designed for durability. It operates reliably within an ambient temperature range of -20°C to 50°C and humidity from 15% to 90% RH (non-condensing), making it suitable for industrial and outdoor air quality monitoring applications.

Can the measurement range be customized?

Yes, while the standard model is configured for 0-20ppm, Renke offers an optional 0-2000ppm range. Furthermore, the manufacturer supports customization for other specific ranges. For custom requirements, direct consultation with the supplier is recommended.

Package Includes

  • 1 x Renke RS-NO2-N01-2-20P Nitrogen Dioxide Sensor Module

Additional Information

Weight 0.165 kg
Dimensions 15 × 15 × 6 cm