SKU: SENS-0834
📋 GST Invoice Available

Asair AO-02 Oxygen Sensor - Electrochemical Partial Pressure Sensor

₹1,839.00 (Inclusive of all taxes)
Out of Stock

The Asair AO-02 is an electrochemical oxygen sensor designed for measuring oxygen concentration from 0 to 100% by volume, featuring a molded body, temperature compensation, and a linear millivolt output suitable for integration into environmental monitoring systems, vehicle exhaust analyzers, and industrial safety applications.

Features

  • Electrochemical partial pressure sensing principle for 0-100% O2 concentration measurement.
  • Linear millivolt output (9-13 mV in ambient air) for direct ADC interfacing.
  • Integrated temperature compensation ensures stable readings across operating conditions.
  • Molded body construction provides durability and resistance to environmental factors.
  • Fast T90 response time for real-time oxygen level monitoring.

Out of stock

Description

The Asair AO-02 oxygen sensor operates on an electrochemical partial pressure principle, generating a linear voltage signal proportional to the ambient oxygen concentration. This self-powered sensor requires no external voltage supply, producing a stable 9-13 mV output in standard air (20.9% O2), making it directly compatible with high-impedance analog inputs on microcontrollers, data loggers, and industrial PLCs.

Engineered with a robust molded body and internal temperature compensation, the AO-02 maintains measurement accuracy and reliability across a wide range of environmental conditions. Its optimized electrochemical cell structure ensures a rapid response to oxygen level changes, which is critical for safety and process control applications where timely detection is paramount.

Key Features

  • Linear Partial Pressure Output: Delivers a 0-100% measurement range with a corresponding linear millivolt signal for straightforward calibration and data acquisition.
  • Self-Powered Operation: As an electrochemical sensor, it generates its own output signal without requiring an external power supply, simplifying system design.
  • Built-in Temperature Compensation: Internal compensation circuitry minimizes reading drift caused by ambient temperature fluctuations, enhancing long-term stability.
  • Fast Response Characteristic: Achieves a T90 response time, enabling real-time monitoring of dynamic oxygen environments.
  • Durable Molded Housing: The sensor body is constructed from molded materials that protect the internal electrochemical cell from physical damage and mild environmental exposure.
  • High Accuracy & Anti-Interference: Designed for precise and reliable oxygen readings with inherent resistance to common electrical and chemical interferences.

Applications

  • Vehicle and engine exhaust gas analysis for emissions testing and combustion efficiency monitoring.
  • Environmental monitoring stations for measuring ambient oxygen levels in enclosed or controlled atmospheres.
  • Industrial safety systems for oxygen deficiency monitoring in confined spaces, laboratories, and manufacturing facilities.
  • Agricultural and controlled atmosphere storage (CAS) systems for regulating oxygen levels in produce storage.
  • Educational and research setups for demonstrating principles of gas sensing and environmental chemistry.

Technical Specifications

Manufacturer Part NumberAO-02
BrandAsair
Item TypeOxygen Sensor
Operating PrinciplePartial Pressure Electrochemical
Measurement Range0 - 100% Vol. O2
Output Signal9 - 13 mV in Air (Linear)
Key FeatureTemperature Compensation
Key FeatureFast Response (T90)
Key FeatureNo External Power Required

Frequently Asked Questions

What is the output signal of the Asair AO-02 oxygen sensor and how do I connect it?

The AO-02 produces a linear millivolt (mV) output, typically 9-13 mV when exposed to standard ambient air (20.9% O2). To read it, connect the sensor's output wires directly to the analog input of a microcontroller (like an Arduino), PLC, or data logger with a high-impedance input. No external power supply is needed for the sensor itself, but your measurement device must be capable of reading low-voltage DC signals.

Does this sensor require calibration, and what is its measurement range?

Yes, for precise measurements, the sensor should be calibrated. Its full measurement range is 0 to 100% oxygen by volume. Calibration typically involves taking a reading in a known reference gas (like 20.9% O2 in clean, dry air) and adjusting your system's scaling factor accordingly. The built-in temperature compensation helps maintain accuracy, but periodic calibration checks are recommended for critical applications.

What are the typical applications for this electrochemical oxygen sensor?

The AO-02 is commonly used in applications requiring oxygen concentration monitoring. Primary uses include vehicle and engine exhaust gas analysis for emissions testing, environmental monitoring of ambient air in enclosed spaces, and industrial safety systems for detecting oxygen deficiency in confined areas. It is also suitable for educational projects and research involving gas detection.

Package Includes

  • 1 x Asair AO-02 Oxygen Sensor

Additional Information

Weight 0.045 kg