SKU: SENS-3331
📋 GST Invoice Available

7Semi SCD40 CO2, Temperature & Humidity Sensor Breakout Module - I2C Interface

₹2,779.00 (Inclusive of all taxes)
Out of Stock

The 7Semi SCD40 breakout module integrates a high-accuracy photoacoustic NDIR CO2 sensor with temperature and humidity sensing, providing comprehensive environmental data via a digital I2C interface (address 0x62) for easy integration with Arduino, Raspberry Pi, ESP32, and other 3.3V/5V microcontroller platforms.

Features

  • High-accuracy PASens photoacoustic NDIR CO2 sensing from 0 to 40,000 ppm
  • Integrated temperature and humidity sensor for complete environmental monitoring
  • Digital I2C communication with a wide 2.4V to 5.5V supply voltage range
  • Ultra-compact breakout board design with pre-soldered header pins
  • Features automatic self-calibration (ASC) for long-term stability (>10 years)

Out of stock

Description

The SCD40 sensor module employs advanced photoacoustic NDIR (PASens) technology for precise CO2 concentration measurement, eliminating the need for a traditional infrared source and detector pair. This design enhances reliability and reduces power consumption. The module includes a fully calibrated digital sensor for temperature and relative humidity, providing compensated and accurate readings.

Its digital I2C interface outputs 16-bit data with a defined command structure, simplifying integration into embedded systems and IoT nodes. The wide operating voltage range ensures compatibility with both 3.3V and 5V logic systems, while the low power consumption makes it suitable for battery-powered applications in HVAC, smart building controls, and indoor air quality monitors.

Key Features

  • PASens photoacoustic NDIR CO2 sensor with ±(40 ppm + 5%) accuracy
  • Integrated temperature and humidity sensing with ±6% RH accuracy
  • Wide measurement range from 0 to 40,000 ppm CO2
  • Digital I2C interface (address 0x62) for straightforward microcontroller communication
  • Supports a broad 2.4V to 5.5V supply voltage for flexible system design
  • Automatic Self-Calibration (ASC) algorithm ensures long-term measurement stability
  • Ultra-compact form factor with a breakout board for easy prototyping
  • Low power consumption optimized for continuous monitoring applications

Applications

  • Indoor air quality (IAQ) monitoring and demand-controlled ventilation (DCV) systems
  • Smart HVAC system integration for CO2-based fresh air intake control
  • Embedded environmental sensing in IoT devices and smart building platforms
  • Portable air quality monitors and data loggers for health and safety compliance
  • Classroom, office, and conference room occupancy and air quality assessment

Technical Specifications

Sensor TechnologyPhotoacoustic NDIR (PASens)
CO2 Measurement Range0 – 40,000 ppm
CO2 Accuracy±(40 ppm + 5%)
CO2 Repeatability±10 ppm
CO2 Response Time60 s
Humidity Range0 – 100% RH
Humidity Accuracy±6% RH
Temperature Range-10°C to 60°C
Operating Voltage2.4V – 5.5V
Communication InterfaceI2C (Address: 0x62)
CalibrationAutomatic Self-Calibration (ASC)
Module Dimensions (LxWxH)30 x 23 x 8 mm
Sensor Dimensions (LxWxH)10.1 x 10.1 x 6.5 mm
Operating Temperature-10°C to 60°C

Frequently Asked Questions

What is the I2C address of the 7Semi SCD40 breakout module?

The default I2C address for the SCD40 sensor is 0x62. This address is fixed and cannot be changed, allowing for straightforward integration with microcontrollers like Arduino, ESP32, or Raspberry Pi using standard I2C libraries.

What is the operating voltage range for this sensor module?

The module supports a wide supply voltage range from 2.4V to 5.5V DC. This makes it directly compatible with both 3.3V and 5V logic systems without requiring a level shifter, simplifying power supply design in embedded projects.

Does the SCD40 require manual calibration?

No, the SCD40 features an Automatic Self-Calibration (ASC) algorithm. When exposed to periodic fresh air conditions (approx. 400 ppm CO2), the sensor automatically calibrates itself, ensuring accurate readings over its operational lifetime of more than 10 years without user intervention.

What is the response time for the CO2 measurements?

The CO2 sensor has a typical response time (t90) of 60 seconds. The integrated temperature and humidity sensors have a slightly longer response time of 90 seconds, providing stable and reliable data for environmental monitoring and control loops.

Package Includes

  • 1 x 7Semi SCD40 CO2, Temperature & Humidity Sensor Breakout Module
  • 1 x Header Pin Strip

Additional Information

Weight 0.003 kg
Dimensions 3 × 2.3 × 0.8 cm