SKU: SENS-0283
📋 GST Invoice Available

MemsFrontier MPM10-BD Laser PM Sensor Module - UART/I2C/PWM Output, Front Airflow

₹989.00 (Inclusive of all taxes)
Out of Stock

The MemsFrontier MPM10-BD is a compact laser-based particulate matter sensor module compatible with 5V microcontrollers (Arduino, Raspberry Pi, ESP32) via UART, I2C, or PWM interfaces. It provides real-time concentration data for PM1.0, PM2.5, and PM10 particles, designed with front-facing air inlets and outlets for optimized sampling.

Features

  • Laser scattering principle detects PM1.0, PM2.5, and PM10 concentrations from 0–1000 µg/m³.
  • Multi-interface output: selectable UART (serial), I2C, or PWM for flexible system integration.
  • High accuracy: ±15 µg/m³ or ±15% reading under standard conditions (25°C, 50% RH).
  • Fast response with power-on settling time under 10 seconds for real-time monitoring.
  • Compact 10-pin module (37.8 x 34.8 x 11.8 mm) with front airflow design for versatile mounting.

Out of stock

Description

The MPM10-BD employs a laser scattering detection principle to accurately measure airborne particulate matter in the 0.3 to 10 µm size range. Its front-mounted air inlet and outlet design ensures consistent airflow across the sensing chamber, enhancing measurement stability in various orientations and environments. The module includes integrated signal conditioning and a microcontroller for direct digital output via UART, I2C, or PWM, simplifying integration into air quality monitoring systems.

Engineered for reliable long-term operation, the sensor operates across an industrial temperature range of -10°C to +60°C and 0–95% RH (non-condensing). With a mean time between failures (MTBF) of ≥5 years, it is suited for continuous environmental monitoring applications in both indoor and outdoor settings, providing stable data output with minimal drift.

Key Features

  • High-precision laser PM sensor for PM1.0, PM2.5, and PM10 mass concentration.
  • Triple-output interface (UART/I2C/PWM) offers maximum compatibility with data loggers and controllers.
  • Optimized front airflow path reduces Particle deposition and improves sampling efficiency.
  • Low operating current (≤85 mA) and standby current (≤45 mA) for energy-efficient designs.
  • Robust construction with a wide operating temperature range for demanding environments.
  • Calibrated factory output ensures reliable data without requiring user calibration.
  • Compact, surface-mount form factor ideal for embedded air quality monitors and IoT nodes.

Applications

  • Embedded indoor air quality monitors for HVAC systems and smart buildings.
  • Portable environmental data loggers for PM pollution mapping and research.
  • Industrial air filtration and dust collection system performance monitoring.
  • IoT-based outdoor air quality monitoring stations for urban pollution tracking.
  • Integration into laboratory equipment for aerosol and particulate matter studies.

Technical Specifications

ModelMPM10-BD
Supply Voltage5.0 VDC
Operating Current≤85 mA
Standby Current≤45 mA
Output InterfacesUART, I2C, PWM
Particle Size Range0.3 – 10 µm
Measurement Range0 – 1000 µg/m³ (PM1.0, PM2.5, PM10)
Accuracy±15 µg/m³ or ±15% reading (at 25±2°C, 50±10% RH)
Response Time≤10 seconds (power-on settling)
Operating Temperature-10°C to +60°C
Storage Temperature-30°C to +70°C
Operating Humidity0 – 95% RH (non-condensing)
Dimensions (L x W x H)37.8 x 34.8 x 11.8 mm
Pin Configuration10-pin
Mean Time Between Failures (MTBF)≥5 Years

Frequently Asked Questions

What communication protocols does the MPM10-BD sensor support?

The MPM10-BD supports three digital output interfaces: UART (serial communication), I2C, and PWM. You select the active interface via hardware configuration or command, allowing direct connection to microcontrollers like Arduino, ESP32, or Raspberry Pi without additional signal converters.

What is the operating voltage and current requirement?

The sensor requires a stable 5.0 VDC supply. During active measurement, it draws a maximum of 85 mA. In standby mode, the current consumption drops to ≤45 mA. Ensure your power source can provide clean, regulated 5V power to avoid measurement noise.

How accurate is the PM concentration measurement?

Under standard test conditions (25±2°C, 50±10% RH), the sensor accuracy is ±15 µg/m³ or ±15% of the reading, whichever is greater. This applies to its PM1.0, PM2.5, and PM10 outputs across the 0–1000 µg/m³ range. Environmental factors like extreme humidity can affect readings.

Does the module include a connector or cable?

No, the module is supplied as a bare PCB with a 10-pin header footprint. You must solder your own connector or wires to the pins. A pinout diagram is required for correct wiring of power, ground, and the selected communication lines (UART TX/RX, I2C SDA/SCL, or PWM).

What is the sensor's response time and operating environment?

The sensor achieves a stable reading within 10 seconds after power-on. It is designed for continuous operation in environments from -10°C to +60°C and 0–95% relative humidity (non-condensing). For outdoor use, a protective housing is recommended to shield it from direct rain and condensation.

Package Includes

  • 1 x MemsFrontier MPM10-BD Laser PM Sensor Module

Additional Information

Weight 0.02 kg
Dimensions 3.78 × 3.48 × 1.18 cm