SKU: SENS-1363
📋 GST Invoice Available

Pro-Range XKC-Y27C-NPN Non-Contact Liquid Level Sensor - DC 5-24V, NPN Output, IP67

₹589.00 (Inclusive of all taxes)
Out of Stock

The Pro-Range XKC-Y27C-NPN is a non-contact capacitive liquid level sensor designed for industrial monitoring applications. Operating on a wide 5-24V DC supply, it provides an NPN output signal for direct integration with PLCs, microcontrollers, and industrial control systems, enabling reliable level detection through non-metallic container walls.

Features

  • Non-contact capacitive sensing through container walls (non-metallic materials only)
  • Wide operating voltage range: 5-24V DC for flexible system integration
  • NPN open-collector output for direct PLC and controller interfacing
  • IP67 waterproof rating ensures reliable operation in harsh, wet environments
  • Adjustable sensitivity for fine-tuning detection across different materials and thicknesses

Out of stock

Description

The XKC-Y27C-NPN sensor operates on a capacitive sensing principle, detecting changes in dielectric constant caused by the presence or absence of liquid on the opposite side of a non-metallic wall. This non-contact method eliminates contamination risks and is ideal for monitoring corrosive, sterile, or viscous fluids.

Featuring a robust IP67-rated housing, the sensor is protected against dust ingress and temporary immersion, making it suitable for demanding industrial environments. Its wide 5-24V DC input range and NPN sinking output provide straightforward compatibility with a vast array of industrial automation hardware and 24V PLC digital inputs.

Key Features

  • Non-contact capacitive sensing technology for hygienic and maintenance-free operation
  • Corrosion-resistant housing and sensing face for long-term reliability
  • Quick response time for real-time level monitoring and control
  • Simple installation via mounting bracket or adhesive, no tank penetration required
  • High-value build optimized for industrial process control applications
  • Durable construction ensures a long operational lifespan

Applications

  • Level monitoring in chemical processing tanks for acids, solvents, and corrosive liquids
  • Fill-level detection in food & beverage production lines within plastic or glass vessels
  • Pharmaceutical batch processing where sterile, non-invasive sensing is critical
  • Water level control in residential and commercial water treatment systems
  • Liquid inventory management in storage containers and intermediate bulk carriers (IBCs)

Technical Specifications

Model NumberXKC-Y27C-NPN
Sensing PrincipleCapacitive (Non-Contact)
Supply VoltageDC 5-24V
Output TypeNPN (Open Collector)
Detection DistanceUp to 10mm (through container wall)
Container MaterialNon-Metallic (Plastic, Glass, etc.)
Protection RatingIP67 (Waterproof & Dustproof)
SensitivityAdjustable
Item TypeLiquid Level Sensor

Frequently Asked Questions

What is the maximum container wall thickness this sensor can detect through?

The sensor is designed for non-contact detection through non-metallic walls, with a typical effective sensing distance of up to 10mm. The actual maximum wall thickness depends on the material's dielectric constant; performance is best with thinner walls of plastics like PVC, polypropylene, or glass. The adjustable sensitivity potentiometer can help optimize detection for specific material and thickness combinations.

How do I wire and interface the NPN output with my PLC or Arduino?

The sensor's NPN output is an open-collector transistor. Connect the brown wire to your positive supply (5-24V DC), the blue wire to ground (0V), and the black wire is the signal output. To read the signal with a PLC digital input or microcontroller, connect the black wire to your input pin and use a pull-up resistor to your logic voltage (e.g., 3.3V or 5V). The output switches to ground (low) when liquid is detected.

Can this sensor detect liquid levels in metal tanks?

No, this specific capacitive non-contact sensor is designed exclusively for use with non-metallic containers. Metal tanks shield the capacitive field, preventing reliable detection. For metal tanks, you would require a different sensing technology, such as an ultrasonic sensor mounted above the liquid, a float switch, or a contact-based conductive or pressure sensor.

What is the purpose of the sensitivity adjustment and how do I calibrate it?

The sensitivity adjustment allows you to fine-tune the sensor's trigger point for optimal performance with your specific container material, wall thickness, and liquid type. To calibrate, install the sensor on the empty container at the desired detection point. Slowly adjust the potentiometer until the sensor's output LED just turns off (indicating 'empty'). Then, fill the container to the detection level and verify the LED turns on (indicating 'full').

Package Includes

  • 1 x Pro-Range XKC-Y27C-NPN Non-Contact Liquid Level Sensor

Additional Information

Weight 0.025 kg
Dimensions 14 × 10 × 3 cm