SKU: SENS-1338
📋 GST Invoice Available

Pro-Range XKC-Y26NPN Non-Contact Liquid Level Sensor - DC 5-12V NPN Output

₹569.00 (Inclusive of all taxes)
Out of Stock

The Pro-Range XKC-Y26NPN is a non-contact capacitive liquid level sensor designed for use with non-metallic containers. Operating on a 5-12V DC supply with an NPN open-collector output, it detects liquid presence through container walls, making it ideal for integration with PLCs, Arduino, and industrial control systems.

Features

  • Non-contact capacitive sensing through container walls for non-metallic vessels.
  • Wide operating voltage range of 5-12V DC for flexible system integration.
  • NPN open-collector output signal compatible with PLCs and microcontrollers.
  • Corrosion-resistant operation suitable for various liquids, including acids and alkalis.
  • Adjustable sensitivity for optimal detection across different container materials and thicknesses.

Out of stock

Description

The XKC-Y26NPN sensor operates on a capacitive sensing principle. It detects changes in dielectric constant caused by the presence of liquid on the opposite side of a non-metallic container wall, triggering its solid-state NPN output. This non-invasive method eliminates contamination risk and is unaffected by scale, color, or transparency of the liquid.

Engineered for stable performance, the sensor features robust signal conditioning circuitry that maintains accuracy across a temperature spectrum from cold to boiling liquids. Its compact, sealed design ensures a long service life in demanding environments, providing a reliable binary level signal for automated control and monitoring applications.

Key Features

  • Non-Invasive Capacitive Sensing: Detects liquid presence through walls of plastic, glass, or ceramic containers without physical contact.
  • Broad Liquid Compatibility: Operates effectively with water, oils, chemicals, acids, alkalis, and other conductive/non-conductive fluids.
  • Solid-State NPN Output: Provides a clean, switch-like signal (open-collector) for direct interface with controllers and relays.
  • Adjustable Sensitivity: Features a potentiometer for fine-tuning detection threshold to accommodate various wall thicknesses and material densities.
  • Wide Voltage Operation: Supports a 5-12V DC input range, compatible with standard logic-level and industrial power supplies.
  • Corrosion & Scale Immune: Sensing performance is not degraded by corrosive media or mineral deposits within the container.
  • Durable Construction: Housed in a rugged, sealed package designed for long-term reliability in industrial settings.

Applications

  • Level monitoring in chemical processing tanks and acid/alkali storage containers.
  • Automatic liquid level control in water treatment systems and filtration units.
  • Overflow protection and low-level alert systems for beverage dispensers and coffee machines.
  • Liquid presence detection in pharmaceutical manufacturing and laboratory equipment.
  • Reservoir management in agricultural irrigation and hydroponic systems.

Technical Specifications

Manufacturer / BrandPro-Range
Model NumberXKC-Y26NPN
Sensor TypeNon-Contact Capacitive Liquid Level
Operating VoltageDC 5 - 12V
Output SignalNPN Open Collector
Detection MethodThrough-wall Capacitive Sensing
Container MaterialNon-Metallic (Plastic, Glass, Ceramic)
Liquid CompatibilityWater, Oils, Chemicals, Acids, Alkalis
SensitivityAdjustable via Potentiometer
Item TypeLiquid Level Sensor

Frequently Asked Questions

What type of containers can this sensor work with?

This sensor is specifically designed for non-metallic containers such as plastic, glass, ceramic, or PVC. It uses capacitive sensing to detect liquid through the container wall. It will not function correctly on metallic tanks as the metal shields the electric field.

How do I connect and use the NPN output?

The NPN output is an open-collector transistor. Connect the sensor's V+ to 5-12V DC, GND to ground, and the signal wire (OUT) to your controller's input pin, typically with a pull-up resistor. The output switches to ground (LOW) when liquid is detected and is open (HIGH) when no liquid is present.

Can this sensor detect hot or boiling liquids?

Yes, the Pro-Range XKC-Y26NPN is designed to maintain stable detection performance across a wide temperature range, including cold, hot, and boiling liquids. The sensing principle is based on dielectric constant, which is largely unaffected by temperature for most common liquids.

How do I adjust the sensor's sensitivity?

A small potentiometer is located on the sensor board. Use a small screwdriver to adjust it. Turn clockwise to increase sensitivity for thicker container walls or lower dielectric liquids. Turn counter-clockwise to decrease sensitivity to prevent false triggers from thin walls or external interference.

What is the maximum container wall thickness it can detect through?

The maximum detectable wall thickness depends on the material's dielectric constant and the adjusted sensitivity. Typically, for common plastics (like PP or PVC) up to 5-10mm thickness is reliable. For best results, test the sensor on your specific container with the liquid present while adjusting the sensitivity potentiometer.

Package Includes

  • 1 x Pro-Range XKC-Y26NPN Non-Contact Liquid Level Sensor

Additional Information

Weight 0.025 kg
Dimensions 14 × 10 × 3 cm