SKU: SENS-0829
📋 GST Invoice Available

Renke RS-H2S-N01-2-100P-2 Hydrogen Sulphide & Temperature/Humidity Sensor - RS485 Modbus, Wall Mounted

₹5,719.00 (Inclusive of all taxes)
Out of Stock

The Renke RS-H2S-N01-2-100P-2 is a wall-mounted industrial-grade sensor combining a hydrogen sulfide (H2S) gas detector with integrated temperature and humidity measurement. It communicates via RS485 Modbus-RTU protocol, making it compatible with PLCs, SCADA systems, and industrial data loggers for environmental monitoring in demanding applications.

Features

  • Integrated H2S gas sensor with 0-100ppm measurement range (expandable to 500ppm).
  • Simultaneous monitoring of ambient temperature (-40°C to +80°C) and humidity (0-100% RH).
  • RS485 interface with standard Modbus-RTU protocol for robust industrial network integration.
  • Wide 10-30V DC power input range and low 0.12W power consumption.
  • Wall-mounted waterproof housing designed for reliable operation in harsh environments.

Out of stock

Description

This sensor employs a constant potential electrolytic principle for H2S detection, offering high sensitivity, wide linearity, and stable long-term performance. The integrated digital temperature and humidity sensor provides accurate environmental compensation and additional monitoring data. The device is engineered for industrial durability, featuring a sealed enclosure suitable for wall mounting in varied indoor and sheltered outdoor locations.

Configuration of the Modbus communication address and baud rate allows for seamless integration into multi-node sensor networks, with a maximum communication distance of up to 2000 meters. Its low power draw and wide operating voltage make it suitable for continuous monitoring systems in remote or power-constrained installations.

Key Features

  • High-precision constant potential electrolytic H2S sensor with excellent repeatability.
  • Dual-function design providing gas concentration plus full environmental (T/RH) data.
  • Robust RS485 Modbus-RTU output for noise-resistant long-distance communication.
  • Wide operating temperature range supports deployment from frigid to hot climates.
  • Wall-mounted, waterproof housing ensures protection against dust and moisture ingress.
  • Low power consumption design for energy-efficient, always-on monitoring systems.
  • User-configurable parameters via Modbus for flexible system integration.

Applications

  • Continuous safety monitoring for H2S leaks in chemical processing plants and refineries.
  • Environmental air quality assessment in wastewater treatment facilities and biogas plants.
  • Occupational health and safety compliance monitoring in industrial workshops and garages.
  • Agricultural and livestock building air quality management to prevent toxic gas buildup.
  • Integrated climate and gas monitoring in greenhouses and controlled agricultural environments.

Technical Specifications

Item TypeGas & Environmental Sensor
Manufacturer Part NumberRS-H2S-N01-2-100P-2
Gas MeasuredHydrogen Sulfide (H2S)
Gas Measurement Range0-100 ppm (Max 500 ppm)
Temperature Measurement Range-40°C to +80°C
Temperature Accuracy±0.5°C
Humidity Measurement Range0 to 100% RH
Humidity Accuracy±3% RH
Output InterfaceRS485 (Modbus-RTU Protocol)
Supply Voltage10-30V DC
Power Consumption0.12W
Operating Temperature-20°C to +50°C
Operating Humidity15% to 90% RH
Communication DistanceUp to 2000 meters
Mounting StyleWall Mounted

Frequently Asked Questions

What is the communication protocol and how do I configure the sensor?

The sensor uses the RS485 physical layer with the standard Modbus-RTU protocol. You can configure the communication parameters, including the slave address and baud rate, by sending specific Modbus commands to the device, allowing it to be integrated into multi-drop networks with PLCs, SCADA, or data acquisition systems.

What is the power supply requirement and how is it wired?

The sensor operates on a wide-range DC power supply of 10 to 30 volts. It features a low power consumption of only 0.12W. Typically, wiring involves connecting the positive and negative power lines along with the RS485 data lines (A/B or D+/D-) to your host controller or converter, following standard industrial wiring practices.

Does this sensor require calibration, and what gases does it detect?

Yes, the integrated electrochemical H2S sensor will require periodic calibration against a known standard gas concentration to maintain measurement accuracy, as is standard for all gas detection equipment. This sensor is specifically designed to detect Hydrogen Sulfide (H2S) gas; it is not cross-sensitive to other common gases.

Can this sensor be used outdoors, and what is its IP rating?

The sensor is housed in a wall-mounted, waterproof enclosure designed for durability. While suitable for sheltered outdoor locations (e.g., under eaves, in instrument boxes), for full exposure to harsh weather, verifying the specific IP rating from the manufacturer's datasheet is recommended to ensure it meets the environmental demands of your application.

Package Includes

  • 1 x Renke RS-H2S-N01-2-100P-2 Hydrogen Sulphide Sensor

Additional Information

Weight 0.17 kg
Dimensions 16 × 15 × 6 cm